S
ERVICE
P
ROCEDURES
84
Jumpers
This section lists the factory default configuration for jumpers on the motherboard.
Jumper configurations should not be changed.
Jumper
Description
JP1
JP1 is the Clear CMOS and Password jumper.
Default configuration: jumper cap installed on pins 1 and 2.
N
OTE
:
Because JP1 is not easily accessed on the motherboard and the
jumper cap is very small, it is not necessary—and could introduce an
error—to remove the jumper cap in order to clear the CMOS settings.
Instead, clear the CMOS by denying power to the motherboard, as
described earlier.
JP2
The jumper cap on JP2 should not be removed.
Default configuration: Jumper cap installed on pins 1 and 2.
JP3
The jumper cap on JP3 should not be removed.
Default configuration: Jumper cap installed on pins 1 and 2.