RIVER IDROTECH 18 - 24 - 24H2O
44
10.3 REPAIR INFORMATION
Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical com-
ponents.
• For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see
).
Fig. 69 - Shutter with fuses to remove
Proceed as follows:
• Remove the frame (see the dedicated chapters).
• After these operations you can have access at the following components: geared motor, ignition plug, ambient fan, fume fan,
ambient probe, fume probe, thermostat, electronic board, pressostat.
• For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and to extract it, un-
screw the two screws lying under the geared motor (vedi
), of the auger, remove the hand rejector inside the hopper
and then unscrew the inner bolt of the auger. (vedi
).To assembly proceed at the contrary.
Fig. 70 - Remove the screws
Fig. 71 - Remove the screw