RIVER IDROTECH 18 - 24 - 24H2O
37
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The fire extinguish
and the stove stops
Empty hopper
Full the hopper.
Auger blocked by a
foreign object (for
example nails)
Clean the auger.
Bad quality pellets
Try other types of pellets.
Pellet drop value too
low "phase 1"
Adjust the pellet loading.
Check if on the
display there is an
"ACTIVE ALARM"
Have the stove checked.
The door does not
close perfectly or the
gaskets are worn
Check the door seal and replace the gaskets.
Ignition step is not
completed
Empty the brazier and repeat ignition.
Clogged exhaust
The exhaust chimney is partially or totally obstructed. Call a skilled
chimney technician to check from the stove exhaust to the chim-
neypot. Clean immediately.
Flames are weak and
orange coloured,
pellets do not burn
properly and the
glass blackens
Not sufficient com-
bustion air
Check as following: probable obstructions of the combustible air
inlet from the back or from the bottom of the stove; burning pot
obstructed holes with too ash remains. Have the fan blades and
auger cleaned. (see SMOKE RPM VARIATION User Manual)
Obstructed exhaust
The exhaust chimney is partially or totally obsturcted. Contact an
expert stove-repairer who checks the stove from the exhaust up to
the chimney pot. Provide immediately for stove cleaning.
Obstructed stove
Provide immediately at the inner cleaning of the stove.
The fume fan is out
of order
The pellets can burn also thanks to chimney flue depression
without the aid of the fume fan. Have the fume fan immediately
replaced. It can be noxious to health to let the stove running
without fume fan.
The exchanger fan
continues to turn
even though the
stove has just cooled
Faulty fume tempe-
rature probe
Replace the fume probe.
Faulty mother board Replace the mother board.