RIVER IDROTECH 18 - 24 - 24H2O
34
Fig. 61 - Vacuum out the ash
Fig. 62 - Vacuum out the ash
8.8
CLEANER BLOCKED
If the burn pot grid does not close correctly, the alarm A23 is triggered. Clean the burn pot. Check that there are no pellets stuck
between grid and burn pot. (see
). Break up the pellets using a pointed tool (see
). Clear the alarm and switch the
stove back on.
Fig. 63 - Burn pot
Fig. 64 - Burn pot
8.9
REPLACING THE OVERPRESSURE RELIEF VALVE FOR THE COMBUSTION CHAMBER
Combustion chamber overpressure rubber spacer “G” (fig.A) may become worn and/or damaged, thereby requiring replacement
once a year to ensure proper system operation.
Replace by following the instructions below:
• Remove the top
• Remove the first ceramic or steel side panel (depending on the type of stove)
• Unscrew the screw-washer-rubber spacer-roller shown in fig.A/C (on both sides of the cover). Then assemble the new kit:
• Align the screw-washer-rubber spacer-roller as shown in fig.C and screw it into the structure.
• Tighten the screw completely.
Now make sure that rubber spacer compression is correct, using the template supplied with the kit:
• Place the template on the cover (fig.B); the head of the screw must barely touch the upper reference. Otherwise, tighten or
loosen the screw until it does.
Содержание RIVER IDROTECH 18
Страница 42: ...RIVERIDROTECH18 24 24H2O 42 10 2 ELECTRONIC BOARD WITH DHW Fig 68 ElectricalboardwithDHW ...
Страница 46: ...NOTE ...
Страница 47: ...NOTE ...