PROBLEM SOLVING (THERMOSTOVE)
PROBLEM
POSSIBLE CAUSES SOLUTIONS
INTERVENTION
In automatic
position, the boiler
always works at
maximum power
Thermostat set to
the minimum
Reset the thermostat temperature.
Room thermostat
in a position that
always detects cold.
Change the position of the thermostat
Faulty temperature
detection probe.
Check and, if necessary, replace the probe
Faulty circuit board
Replace board
The boiler does not
start
Power failure
Make sure the power cable is plugged in and the main switch is in
the “I” position.
Blown fuse
Replace the fuse.
Clogged smoke duct
or exhaust
Clean the smoke exhaust and/or smoke duct.
Water temperature
probe has tripped
Call customer service
Temperature does
not increase with
the boiler working
Improper combu-
stion adjustment.
Check recipe and parameters.
Dirty boiler/system
Check and clean the boiler.
Insufficient boiler
power.
Make sure the boiler is appropriately proportional to the system
requirements.
Poor quality pellets
Use quality pellets