1

7027-802C

June 4, 2019

NOTICE: DO NOT DISCARD THIS MANUAL

R

CLASSIC BAY 1200 PELLET 

APPLIANCE

MODEL(S):

CB1200-C

Owner’s Manual

Operation & Care

INSTALLER: Leave this manual with party responsible for use and operation.

OWNER: Retain this manual for future reference.

Contact your dealer with questions on installation, operation, or service.

Installation and service of this appliance should be performed by 

qualified personnel. Hearth & Home Technologies recommends 

HHT Factory Trained or NFI certified professionals.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during 

operation AND cool down.

Hot glass will cause burns.

•  Do not touch glass until it is cooled.

•  NEVER allow children to touch glass.

•  Keep children away.

•  CAREFULLY SUPERVISE children in same room 

as fireplace.

•  Alert children and adults to hazards of 

high temperatures.

•  High temperatures may ignite clothing or other 

flammable materials.

•  Keep clothing, furniture, draperies and other 

flammable materials away.

If the information in these instructions 

is not followed exactly, a fire may result 

causing property damage, personal injury, 

or death.

WARNING

• 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

• 

Do not over fire

 - If appliance or chimney connector 

glows, you are over firing. Over firing will void 

your warranty.

• 

Comply with all minimum clearances to combustibles 

as specified. Failure to comply may cause house fire.

CAUTION

Check building codes prior to installation.

•  Installation MUST comply with local, regional, state 

and national codes and regulations.

• 

Consult local building, fire officials or authorities 

having jurisdiction about restrictions, installation 

inspection, and permits.

CAUTION

Tested and approved for wood pellets and shelled field 

corn fuel only. Burning of any other type of fuel voids 

your warranty.

NOTE:

 To obtain a French translation of this 

manual, please contact your dealer or visit 

www.quadrafire.com

REMARQUE :

 Pour obtenir une traduction française de 

ce manuel, s’il vous plaît contacter votre 

revendeur ou visitez 

www.quadrafire.com

Содержание CLASSIC BAY 1200

Страница 1: ...r flammable materials away If the information in these instructions is not followed exactly a fire may result causing property damage personal injury or death WARNING Do not store or use gasoline or o...

Страница 2: ...ILE HOMES Do not install appliance in a sleeping room An outside combustion air inlet must be provided The structural integrity of the mobile home floor ceiling and walls must be maintained Refer to m...

Страница 3: ...9 C Combustible Materials 9 D Fuel Material and Fuel Storage 9 E Before Your First Fire 10 F Filling the Hopper 10 G General Operating Information 10 H Starting Your First Fire 11 I Fire Characterist...

Страница 4: ...ctronic components and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceramic...

Страница 5: ...anging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted...

Страница 6: ...to water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS WA...

Страница 7: ...r calorifique l efficacit de l aide de donn es recueillies lors d mission de l EPA des tests Une gamme de BTU sorties calcul e l aide de l HHV l efficacit et le taux de br lures de l EPA des tests Bas...

Страница 8: ...own to the State of California to cause birth defects or other reproductive harm For more information go to WWW P65Warnings ca gov Improper installation adjustment alteration service or maintenance ca...

Страница 9: ...ared to pellets depending on the quality of the corn used Corn must be free of debris Never burn corn straight from the field It will clog the auger mechanism Corn with excessive grain dust must be sc...

Страница 10: ...nformation 1 Thermostat Calls For Heat The appliance is like most modern furnaces when the thermostat calls for heat your appliance will automatically light and deliver heat When the room is up to tem...

Страница 11: ...short active flame pattern that extends out of the fire pot approximately 4 to 6 inches 102 to 152mm If the fire has tall flames with black tails and seems somewhat lazy the feed rate will need to be...

Страница 12: ...ppliance Restart Process 1 When the unit has run out of fuel add pellet fuel to the hopper 2 Dump the ashes and clinkers built up in the fire pot by pulling the ash dump removal handle out several tim...

Страница 13: ...ne for Saturday and Sunday Manual Non Programmable In this setting there are no program routines for the thermostat to follow and the temperature control will be set only by the UP and DOWN buttons on...

Страница 14: ...l move TEMPERATURE switch to OFF and back to HEAT again Figure 14 1 Q Thermostat Temperature Programs The thermostat by default has 4 separate program events they are MORN DAY EVE and NITE Each event...

Страница 15: ...ngs To Lock the Keypad 1 Move TEMPERATURE switch to HEAT 2 Move SET switch to RUN 3 Perform a single press of each button in the following sequence NEXT NEXT NEXT HOLD A padlock will appear on the dis...

Страница 16: ...y icon Figure 16 4 Low battery icon Figure 16 2 Power Outlet Terminal Block Center 2 screws for Thermostat Wires CONNECT THERMOSTAT WIRES TO APPLIANCE There is a 4 screw terminal block located on the...

Страница 17: ...noisy blowers is from the impellers becoming dirty over time See maintenance and service section for maintaining and servicing What is the metal object with the bend in it that came inside the plastic...

Страница 18: ...re OR X Heat Exchanger Drop Tube Every 1 ton of fuel OR X Hopper Every 1 ton of fuel or when changing fuel types OR X Top Vent Adapter More frequently depending on the fuel type or ash build up OR X V...

Страница 19: ...ed every time you clean the firebox Remember to place the ash and debris into a metal or noncombustible container e The cleaning rods must be fully closed when cleaning is complete See Disposal of Ash...

Страница 20: ...meowner a Be sure the appliance is allowed to cool has been unplugged and the exhaust blower is off b A more thorough cleaning is needed to remove the excess ash that is left behind from the use of th...

Страница 21: ...iance is allowed to cool has been unplugged and the exhaust blower is off The products of combustion will contain small particles of fly ash The fly ash will collect in the exhaust venting system and...

Страница 22: ...meowner a Be sure the appliance is allowed to cool has been unplugged and the exhaust blower is off b To inspect the door rope gasket open the door and see that the door rope extends approximately 1 8...

Страница 23: ...ldup exceeds the half way point in the fire pot IMMEDIATE ATTENTION AND CLEANING IS REQUIRED D Soot or Creosote Fire Establish a routine for the fuel wood burner and firing technique Check daily for c...

Страница 24: ...d pellets in fire pot Fire pot clean out plate not closed Fire pot is dirty The ignition hole between the igniter bracket and fire pot is blocked Igniter not working Control box defective Check that f...

Страница 25: ...ails to start or does not shut off Blower not plugged in Blower is clogged with ash Blower is defective Control box is defective Check that blower is plugged into wire harness Clean exhaust system Rep...

Страница 26: ...tep b of Remove existing blower to secure blower to housing c Re connect wiring use jumper wire if necessary Re connect power supply Remove 2 Screws Remove 4 Screws Outside Air Flex Hose Convection Bl...

Страница 27: ...he ash drawer Double check that the igniter wires are clear of any movement i e ash drawer fire pot cleaning rod etc 6 Re install the ash drawer and side panel and re connect the power Igniter Igniter...

Страница 28: ...the side frame Use a powered Phillips head screw driver to remove the 4 screws 2 Replacing Side Glass Glass is 5mm thick high temperature heat resistant ceramic glass DO NOT REPLACE with any other mat...

Страница 29: ...blue light will automatically start blinking 1 blink every 10 seconds for the first 60 seconds and then will stop 7 Heat Exchangers The heat exchangers transfer hot air from the exhaust system into c...

Страница 30: ...m which will turn off the appliance if an over fire condition should occur or if the convection blower should fail to operate 19 Snap Disc 3 Back Burn Protector 250 F Snap disc 3 is mounted on the sid...

Страница 31: ...minal Block Center 2 screws for Thermostat Wires Cleaning Rods Heat Exchanger Tubes Figure 32 1 Figure 32 2 Figure 32 3 Heat Output Fan Speed Reset Button Call Light HIGH HIGH MED LOW LOW Outside Air...

Страница 32: ...32 7027 802C June 4 2019 CB1200 Free Standing C Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 33: ...33 7027 802C June 4 2019 CB1200 Free Standing Date of Service Performed By Description of Service...

Страница 34: ...ufacturing Date March 2019 Ending Manufacturing Date Active Classic Bay Freestanding Pellet Stove Part number list on following page 06 19 1 6 2 7 8 9 3 4 5 10 11 12 13 14 15 16 17 17 22 18 19 20 21 2...

Страница 35: ...2 220 0490 12 Y Hopper Lid Magnetic Switch SRV7000 375 Y 2 Baffle Assembly Left 510 5350 3 Baffle Assembly Right 510 5360 4 Hinge Plate 812 4030 Hinge Door Male SRV450 2810 Screw Pan Head Phillips 10...

Страница 36: ...ement Assembly 18 Loop Igniter Pkg of 1 SRV7000 462 Y Pkg of 10 SRV7000 462 10 Y Wing Thumb Screw 8 32 X 1 2 Pkg of 24 7000 223 24 Y 11 2 Combustion Plenum Trap Door 812 4100 12 Thermocouple Cover Qty...

Страница 37: ...y 6 req 229 0640 Y 23 Snap Disc Convection Blower 1 SRV230 0060 Y 24 Convection Blower 130 60 CFM 812 3370 Y Nut Keps Lock 8 32 Pkg of 40 226 0060 40 Y Screw Pan Head Philips 8 32 X 3 4 Pkg of 24 229...

Страница 38: ...SRV240 0450 Y 37 Control Board 3 Speed SRV7000 704 Y Fuse 8 Amp Control Box Pkg of 10 812 3780 10 Y 38 Cover Control Box 410 6321 39 Feed Adjustment Plate 812 4170 40 Cover Feed Motor 410 5311 41 Feed...

Страница 39: ...SSORIES Collar Offset Top Vent 812 3570 Damper 3 Inch Tall Vertical Installs Only PEL DAMP3 Y Damper 4 Inch Tall Vertical Installs Only PEL DAMP4 Heat Exchange Repair Kit 812 4970 Log Set 811 0592 Out...

Страница 40: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...