Step 10 – Connect
C-more
6” Color Micro-Graphic Panel to PLC
Connect the serial communications cable between the
C-more
Micro-Graphic panel and the
PLC. The panel can be connected to the PLC via the panel’s built-in 15-pin serial
communications port with either RS-232, RS-422 or RS-485 communications.
EA1-TCL-M Hardware User Manual, 1st Ed., 12/09
1–16
Chapter 1: Getting Started
1
®
Port 2
Port 2
PSP-24-024S
Power Supply
Recommended
DC Supply Fuse
750 mA fast acting,
ADC p/n AGC-75
EA 2CBL
serial cable
C-more
6-inch Color
Micro-Graphic
Panel
CLICK PLC
Port
2
Port
2
C-more
to
Direct
LOGIC
VGA 15 pin port
serial cable
p/n EA 2CBL 1
DL-06 PLC
PSP-24-024S
Power Supply
Recommended
DC Supply Fuse
750 mA fast acting,
ADC p/n AGC-75
C-more
Color 6 Inch
Micro-Graphic
Panel
Example of panel’s Port 2
connected to a CLICK PLC
Example of panel’s Port 2
connected to a DL06 PLC