3
Service menu settings
Logamax Plus GB062
12
3.2.2
Menu 2
To call up a service function in this menu:
B
Hold down “Back”, + and – at the same time until
L.1
is
shown on the display.
B
Press – until
L.2
is shown on the display.
B
Press OK to make settings in menu 2.
B
Press + or – to scroll through the menu's service
functions.
Service function
Possible settings/comments/displays
8.A
Software version
The current software version is displayed.
8.b
Display soft code number
8.C
Display internal status code
internal parameter
8.d
Display internal fault code
internal parameter
8.E
Returning the appliance to its
standard settings
This service function enables you to reset the appliance to its standard set-
tings.
Setting 00.
8.F
Ignition test (permanent)
•
0 = Off
•
1 = On
9.A
Permanent operating mode
This function permanently sets an operating mode.
The following settings are possible:
•
0: Standard operation; the appliance runs according to controller specifi-
cations.
•
1: The appliance runs at minimum output.
•
2: The appliance runs at maximum output.
Default setting : 0.
9.b
Actual fan speed
Actual fan speed in Hz
9.E
Signal turbine delay
(Combi version)
Through spontaneous pressure change in the water supply, the flow meter
(turbine) can signal that water is being drawn off.
This means the burner starts briefly although no water is drawn off.
The turbine signal delay can be set from 1 to 8. One step corresponds to
0.25 seconds.
Default setting : 4 (0,25 seconds).
9.F
Heating circuit pump overrun time
The pump overrun time is started by the control system at the end of the
heat demand.
The following settings are possible:
•
1 to 10: overrun time in minutes (steps of 1 minute)
Default setting : 3 minutes.
A.A
Temperature at flow temperature
sensor
This service function allows you to display the temperature at the flow tem-
perature sensor.
Tab. 4
Menu 2
Содержание Logamax GB062-24 KDE H V2
Страница 57: ......