5
Electrical values, gas conversion and boiler layout
Logamax PLus GB062
41
5
Electrical values, gas conversion and boiler layout
5.1
Sensor (NTC) Values
5.1.1
Domestic hot water temperature Sensor
5.1.2
Central Heating Flow Temperature Sensor,
Storage Tank Temperature Sensor
5.1.3
Outdoor Temperature Sensor (7.747.026.229)
Temperature ( °C)
Measure Tolerance
±
%10
Resistance (
Ω
)
0
28704
10
18410
20
12171
25
10000
30
8269
35
6881
40
5759
45
4847
50
4101
55
3488
60
2981
65
2559
70
2207
75
1912
80
1662
85
1451
90
1272
Tab. 10 Domestic hot water temperature Sensor
Temperature ( °C)
Measure Tolerance
±
%10
Resistance (
Ω
)
20
14772
25
11981
30
9786
35
8047
40
6653
45
5523
50
4608
55
3856
60
3243
65
2744
70
2332
75
1990
80
1704
90
1262
100
950
Tab. 11 Central Heating Flow Temperature Sensor,
Storage Tank Temperature Sensor
Temperature ( °C)
Measure Tolerance
±
%10
Resistance (
Ω
)
-20
95893
-15
72228
-10
54889
0
32506
10
19860
20
12486
30
8060
5.1.4
Buderus Outdoor Temperature Sensor