D45

System technical guide

TECHNICAL

 GUIDE

 

2011

D4

5

Release 01 – S

ept

ember 2011

Содержание D45

Страница 1: ...D45 System technical guide TECHNICAL GUIDE 2011 D45 Release 01 September 2011 ...

Страница 2: ......

Страница 3: ...OOR ENTRY SYSTEM D45 Video Door Entry System General features and devices overview 02 Installation rules 73 Configuration concept and examples 95 Troubleshooting 124 System topology layout examples 127 Wiring diagrams 137 ...

Страница 4: ...gs n Audio and video signals are transmitted differently with better performance in terms of electronic disturbance immunity n The system automatically equalizes and amplifies the video signal restoring high quality video performance even for long distances using CAT 5 cable n Smart system power supply all system devices detect the power load status automatically and work in normal power mode ther...

Страница 5: ...07 DIN Rail 72 105 33 mm 30V 2 5mA 30V 70 mA ENTRANCE PANELVIDEO MIXER 323004 DIN Rail 72 105 33 mm 30V 20 mA 30V 60 mA DISTRICT GENERATOR 323013 DIN Rail 175 105 66 mm 30V 100 mA 30V 300 mA SYSTEM EXP INTERFACE 323019 DIN Rail 106 105 33 mm 30V 50 mA 30V 80 mA BASIC APARTMENT INTERFACE 323008 DIN Rail 72 105 33 mm 30V 40 mA 30V 140 mA POWER SUPPLY 323005 Wall mount 167 5 161 85 mm AC input 220V D...

Страница 6: ...software can be updated with no need to open the cover n The keyboard is designed with an automatic night lamp n It will automatically send an alarm for overtime door opening n It can set the video menu n CCD Super brightness LED Light Compensation n The parameters of the entry panels can be set n Door lock release with password Entrance panel functions overview DigitalcolourEP 322010 Digital entr...

Страница 7: ...tion Lamp 17 SYSTEM BUS uses CAT5 cable to connect to system 18 7P connector 12 V GND supply power to A C module DOOR LOCK RELEASE door lock release signal output by A C module GND DAS electronic lock status signal connector LOCK LOCK connect electronic lock 19 SPK OUT GND GND SPK OUT connect entrance panel loudspeaker 20 V GAIN video gain setting 21 ANT connector for A C module antenna 22 RESET f...

Страница 8: ...button of the handset to cycle through other entrance panels 322010 DIGITAL EP Call by the visitors 1 A visitor can input the resident s number as per the prompt on the display and press the key for confirmation The unit shall send out the call signal displaying the message calling please wait It can establish two way communication and at the same time transmit the image to the handset Now the res...

Страница 9: ... itwillfail Whenstartingthisfunction thereforerefertothesetting Alarm for overtime door opening When the lock status signal type has been correctly set and the riser door is open for over 120 seconds the corresponding entrance panel will send an alarm to the Switchboard Note Thisfunctionrequiresthattheelectricdoorlockontheentrancepanelisfitted withalock status openandclose signaloutput anditwillon...

Страница 10: ...e anti removal alarm function 4 Select 4 to complete the mode setting of the room number Eight options are available for your selections When using the entrance panel as the Riser EP or secondary EP the first and the second mode can be selected When using it as the Backbone EP or main EP the 3rd 4th 5th 6th 7th and 8th mode can be selected depending on the actual situations The default factory set...

Страница 11: ...ancepaneldoesnotusetheparameter oftheconfigurator Forexample acertainplacehasbeenconfiguredofits resistance andthissettingshallbeinvalid 6 Select 6 to setup language you can setup english or other languages 7 Select 7 to setup pulse width for unlock 1 to 99 seconds can be set for lock opening pulse 8 Select 8 to set the password door lock release function As per the prompt on the display we can en...

Страница 12: ...f the speakers When used as Backbone EP or main EP it can download the address book using the computer Online update of programs It can download or update the software through the ISP port no need to open the cover Points to consider when adjusting the camera When adjusting the head up or down the angle can t be too wide or vignetting may occur Points to consider when installing the electric door ...

Страница 13: ...e receiver of the handset to start conversation 2 SPK and MIC adjustments at the back of the Small EP could be used to adjust the volume of this device and the handset 3 Small EP cannot be installed with the camera directly facing the sun Legend 1 Camera 2 Microphone 3 Call key 4 Loudspeaker 5 SPK to adjust the volume of sound coming from the handset to this device 6 R1 to connect the R1 terminal ...

Страница 14: ...handset with alarm can be connected to the D45 EP through the main system riser The main system riser can be connected to the Switchboard to perform functions such as conversation monitor and VDE functions All handsets have an elegant and outstanding outlook and complete functionality which makes it possible for them to offer top security service and to be the ideal choice for the modern house Fun...

Страница 15: ... Number keys and corresponding numbers 15 Alarm zone LEDs 1 to 8 16 Display screen 17 Anti removal switch 18 Master and Slave pin selection 19 Configurators socket 20 BUS connector 21 SOS alarm connector 22 SEP 322020 connector 23 Alarm sensors connector see Wiring diagram 15 24 Door lock interface 323015 connector 25 Anti removal sensor connector 26 Serial interface connector 1 2 3 4 5 6 7 8 9 10...

Страница 16: ...m zone LEDs 1 to 8 9 Display screen 10 Microphone 11 Door lock release key 12 Monitor key 13 Switchboard call key 14 Answer key 15 SOS key 16 Information LED 17 Download connector 18 Small EP connector 19 Master and slave pin 20 Room number configurator connector 21 BUS connector 22 SOS alarm connector 23 Alarm sensors connector see Wiring diagram 15 24 Door lock release device connector 25 Sensor...

Страница 17: ...one LEDs 1 to 8 8 CRT screen 9 Door lock release key 10 Monitor key 11 Switchboard call key information LED 12 SOS key 13 Sensor anti removal alarm connector 14 Alarm sensors connector see Wiring diagram 15 15 Small EP connector 16 Door lock release device connector 17 Master and slave pin 18 Download connector 19 Room number configurator connector 20 SOS alarm connector 21 BUS connector 321030 B ...

Страница 18: ...0 LEGEND 1 Ring control knob 2 Brightness control knob 3 Contrast control knob 4 Shortcut key 5 Number key 6 Loudspeaker 7 Alarm zone LEDs 1 to 8 8 CRT screen 9 Door lock release key 10 Monitor key 11 Switchboard call key information LED 12 Answer key communication LED 13 SOS key 14 Microphone 15 Sensor anti removal alarm connector 16 Alarm sensors connector see Wiring diagram 15 17 Small EP conne...

Страница 19: ...able all the burglar zones 1 long tone will be heard Note 1 Reason for unsuccessful zone enable note 3 If all zones are disabled this operation will enable all the zones connected to sensors if the operation is successful 1 long tone if not 3 short tones Quit setup mode 1 short tone other Unsuccessful operation 3 short tones Note1 setdefaultparameterandsettingrange Items defaultparameter settingra...

Страница 20: ...om key then long press monitor key and release Video door entry functions Instructions 1 For all pushbuttons the operation is only performed after the pushbutton is released When holding the pushbutton down is required the pushbutton should only be released after an extended beep is heard 2 Operation indication a short or a long beep indicates successful operation 3 short beeps or busy tone indica...

Страница 21: ...utton on the panel The SOS alarm message will be sent to Switchboard by pressing SOS button External SOS alarm The SOS alarm message will be sent to Switchboard by pressing external SOS key For the setting method please refer to the Installation setting operation list table The default status of the external SOS is always NO Alarm operation and alarm sending Alarm zone connectors This device has 8...

Страница 22: ...gurator To set room number 0806 insert configurators 0 8 0 6 in the relevant sockets for the detailed operations please refer to the system configuration chapter Note iftheroomnumberissetbeyondtheapartmentnumbersofeachfloor thenthesettingswillbeconsiderasineffective n Settheroomnumberusingthekeyboard Thismethodhas low priority This means that if the configurator method is also used the handset wil...

Страница 23: ...id cable cutting When connecting sensors a 10 KΩ parallel resistor a 10 KΩ resistor in series are required Resistors should be placed close to the sensor port in order to ensure that an alarm can be sent when the handset is forcefully removed Note IU can afford 12 Vdc sensors type and total sensors current should not exceed a maximum of 300 mA If maximum current is more than 300 mA than an additio...

Страница 24: ...will indicate status of this setting item 1 Get all the default parameters message light on 1 long tone 0 Do not get all the default parameters message light off 1 long tone return to main menu of installation setup 1 short tone other unsuccessful operation 3 short tones Enable and disable sensors 21 Message light is off 8 alarm lights will indicate status of each alarm zone 1 1 1 alarm zone with ...

Страница 25: ...00 s 1 long tone only LED 2 will on 3 delay 150 s 1 long tone only LED 3 will on 4 delay 210 s 1 long tone only LED 4 will on 5 delay 255 s 1 long tone only LED 5 will on return to main menu of installation setup 1 short tone other unsuccessful operation 3 short tones Enable and disable sound alarm for thief 26 The Information LED indicates the setup state 1 enabled if there is a burglar alarm lou...

Страница 26: ...s will be performed normally with the exception of the alarm function Wait 10 seconds and reconnect the power and correct the mistake Reset the alarm zone the handset will start operating normally 3 Cannot enable the alarm zone If the alarm zone cannot be enabled do the following Hardware ensure that the sensors are connected correctly Software in order to enable the zones it will first be necessa...

Страница 27: ...tupstatuswithoutselectinganysubmenus Note duringtheinstallationsetupthehandsetcannotmakecalls Ifanycallis received ashortsoundwillbeheardasindication Howeverthehandsetwillbe unabletoanswer Functions 322040 is an audio handset It has basic functions such as VDP and door lock release It s small in size and has a low power consumption Outlook and connector Introduction Unless otherwise specified the ...

Страница 28: ... heard and the number will be not saved Exit 1 Press the door lock release pushbutton to move to the last item Press the door lock release pushbutton again to exit household number setup and return to the initial installation setup status 2 If the operation is performed wrongly 3 short beeps will be heard the unit will automatically return to the initial installation setup status Example If the ho...

Страница 29: ...3 short beeps will be heard the unit will automatically return to the initial installation setup status Set external SOS to be NO NC FUNCTIONS operation REMARKS Select the setup submenu for SOS NO NC While in the initial installation setup status press and hold the MC pushbutton five times to enter the setup submenu for SOS NO NC Read the current parameter If it s NO the parameter is 1 and the mes...

Страница 30: ...sage light is on When the parameter is 0 the handset is unable to use the doorbell function and the message light is off During setup the parameter will be saved automatically Exit 1 Press the door lock release pushbutton to exit the current submenu and return to the initial installation setup status 2 If the operation is performed wrongly 3 short beeps will be heard the unit will automatically re...

Страница 31: ...l is coming The display will show the picture recorded by EP camera press the answer pushbutton or pick up the handset to accept the calls While the system is busy with the conversation the call light will flash slowly Press the answer pushbutton or put down the receiver to end the call and the device will come back to standby status Unless otherwise specified EP in this manual means main EP or UE...

Страница 32: ... is received the handset will terminate the current communication and answer the incoming call If while the handset is communicating with an internal handset a call from the EP the Switchboard or the Small EP is received the handset will terminate the current communication and answer the incoming call Door lock release When the handset and the EP are in communication press the door lock release pu...

Страница 33: ...nd other Switchboards with colour display can record alarms and call event It can make calls using shortcut key perform cycle monitoring call forwarding and the main Switchboard own functions It s capable of saving thousands of calls and alarm records It provides quick message retrieval according to handset address LEGEND 1 Handset 2 Screen 3 Confirm key 4 Left key 5 Up key 6 Right key 7 Down key ...

Страница 34: ...m ON OFF 700 1000 m ON ON Note Theabovevideogainsettingdataarejustforreference Toadjustandsetdata takeintoaccounttheactualimage Main features Hardware features 1 Using a standard RJ45 interface making it easy to install and connect different systems as a network and managed as districts 2 Audio and video signals are differential signal and a twisted pair is used for their transmission The image is...

Страница 35: ...faults The function is active and the cycle check interval can be set 6 Sort system classify main Switchboard and subsystem Switchboards Main Switchboard can only be installed on backbone BUS Subsystem Switchboards can be installed on riser BUS 7 Communication record management capable of recording thousands of communication records which are easy to browse 8 Alarm recording process possibility of...

Страница 36: ...face select missed calls and delete by press OK All missed call records will be deleted Follow the same procedure to delete answered calls dialled calls 6 monitor use the navigation key to choose this icon press OK to enter the monitoring interface 7 Alarm records use the navigation key to choose this icon and then press OK to enter alarm record interface Press key to check the next record For unp...

Страница 37: ...g the address range managed by item 323003 and selecting the system configuration mode Only if the configuration is correct can thesystemworkcorrectly Thereare3configurationmethods The configurator alternative enjoys the highest priority If the physical configurator is used on the Riser shunt then the other configuration methods will be ineffective Note ifusephysicalconfiguratormethodisused thepow...

Страница 38: ...itconfiguration The CFG light will be off n If the operation is successful the CFG light will flash slowly once and then come on steady If the configuration is not successful the CFG light will be off For example configure CF4 as 5 1 Enter configuration status in standby press input key S1 and hold for 2 s 2 Enter the configuration number press S2 3 times 3 Confirm the configurator number press S1...

Страница 39: ...n floors Using a signal cable each apartment handset is connected to the BUS through item 323002 One 323002 can be connected to 4 handsets The device converts the BUS video signals to transfer mode and then distributes them to the connected handsets 1 2 POWER 7 6 5 4 3 2 1 1 2 ON OFF LEGEND 1 Connect four handsets separately 2 Connect four handsets separately 3 Connect four handsets separately 4 C...

Страница 40: ...cial requirements of villas Directions to the setting of the video gain switch up being ON and down being OFF Note userscanturntheswitchatanylinelenghtanddirectlyverifythe settingeffect FordetailsonhowtoadjusttheB Wimage refertofloorshunt specifications Villashunt 1 2 POWER 1 2 3 4 4 1 2 ON OFF Video gain setting instruction switch up ON switch down OFF B W Signal Distance 1 2 200 m OFF OFF 200 40...

Страница 41: ...IS E R E P P S S Y S T E M IN S Y S T E M O U T IN P W I U 4 O U T S U B S Y S T E M I U 1 I U 2 I U 3 V G A IN V C C O U T G N D B A T T B A T T U T 1 O U T 2 O U T 3 V C C O U T G N D B A T T B A T T U T 1 O U T 2 O U T 3 323002 323010 SEP handset 323016 FloorShunt323002 MAX200m 323003 323005 EP RiserShunt323003 RiserShunt 323003 VillaShunt323016 ...

Страница 42: ...separately powered as there are many handsets they need to be powered separately n When the detached villa is only fitted with one handset this can be connected to Floor shunt If there are 2 to 5 handsets one Apartment Interface needs to be added for expansion and the Small EP must be connected to the Apartment Interface n The distance between the Villa shunt and the handset must be less than 50 m...

Страница 43: ... villa then connect the handset to the Floor shunt One Floor shunt is used for one house If there are 2 to 5 handsets in one house one Apartment Interface should be connected to the Floor shunt HANDSET port for expansion All the handsets will connect to the Apartment interface and One Floor shunt must be used for each house n For town villas fitted with the Small EP the installation is just the sa...

Страница 44: ...323004 Entrance panels video mixer The 323004 enables connection of up to 5 entrance panels providing management of the calls to the riser the first entrance panel from which the call is made has priority It is possible to connect in cascade several handsets item 323004 LEGEND 1 Entrance panels 1 2 3 4 5 connect to entrance panel output interface 1 5 6 Entrance panel OUT connect the system BUS 7 A...

Страница 45: ...g different gears It mainly use in riser systems to divide the riser BUS into many channels to adapt to the wiring in many low electricity wells One building that is particularly high will use 323007 to adjust video gains by splitting in two channels One channel will be used for lower floors the other is for higher floors 323007 also can be used for physically connecting the Switchboard and extend...

Страница 46: ...et When one apartment has 2 or 3 handsets please use this device to extend interfaces Basicapartmentinterface LEGEND 1 Connector for handset 3 2 Connector for handset 2 3 Connector for handset 1 4 System BUS input 5 Accessory power supply input 30 Vdc Note 1 4 these four terminals are RJ45 connectors use CAT5 cable POWER 5 4 3 2 1 System accessories functions overview ...

Страница 47: ... configuration and firmware update 3 Analogue small entrance panel connections 4 Electrical door lock connector 5 Small entrance panel expansion microswitch setting factory set to DOWN position SWITCH UP position enable multi gate interface expansion SWITCH DOWN position only one gate enabled 6 Power supply source selection switch SWITCH UP position system power supply power source enabled SWITCH ...

Страница 48: ...upply We recommend using the auxiliary Power supply If the power consumption of five handsets is not more than the supply provided by one power supply then these five handsets can all be set as the master handsets System accessories functions overview 323002 323010 handset handset handset handset handset 323009 323015 322020 ToHANDSET1 ToHANDSET2 ToHANDSET4 Systemoutput connectnext323002input Syst...

Страница 49: ...f powered through the unit bus system only one indoor unit can be set as the master indoor unit handset 323002 handset handset handset handset 323009 323015 322020 ToHANDSET2 ToHANDSET3 ToHANDSET4 Systemoutput connectto323002 input Systeminput connectto323002 output ...

Страница 50: ...erent types of needs LEGEND 1 Power input end to DC15 30V drive positive locks to DC18 30V drive negative locks 2 External manual door lock release switch 3 Input end of the control signal it can connect the door lock release signal of EP or the door lock release signal of the handset 4 Connect the negative or positive locks When connecting the negative locks it can control two negative locks maxi...

Страница 51: ...010istheauxiliarypowersupplyfor theEP sometimes whenthereareseveralEPsinoneunit orifthemainEPlines aretoolong auxiliarypowersourcesareneeded Thedoorlockaccessorycan eitherbeconnectedtothispowersourceortotheexternalDC18V 30V 2Apower transformer Example Typical Wiring of the door lock accessory PWS Limitdistance 250m Limitdistance 20m Manualpushbutton LinespecificationRVV2x1 0mm2 323010 323005 32301...

Страница 52: ...arately LEGEND 1 POWER Input connector main system power supply 2 POWER Input connector main system power supply 3 Switchboard Connector for Switchboard 4 Main EP Connector for wall EP 5 D1 Riser shunt branch 1 6 D2 Riser shunt branch 2 7 D3 Riser shunt branch 3 8 D4 Riser shunt branch 4 9 Configurators socket 10 Adjust switch for branch 2 video gain 11 Adjust switch for branch 1 video gain 12 Adj...

Страница 53: ...ht will be off If no key is pressed for 10 s during the operation the device will automatically switch to standby The CFG light will be off The video gain setting can be divided into 5 branches branch1 branch 2 branch 3 branch 4 wall EP or release message to handset channel They can all be set according to the instruction data in following table However these data may be different during actual in...

Страница 54: ...d the BT 2 wire IP system It ensures compatibility with the D45 system and BT 2 wire system 1 5 3 2 6 7 4 F453AV 0319 06 USB USB Speed Full Link Aux System 346890 0319 06 USB USB ETH DC SCS AV IN SCS AV SCS AV OUT Speed Full Link Aux System Speed Connection ON 100Mbit OFF 10Mbit Full ON fullduplex OFF halfduplex Link ONindicatesthepresenceoftheEthernetnetwork Aux Push buttonnotused System Whenconn...

Страница 55: ...T3 5 which means that before installing the D45 IP interface Config 3 0 NET3 5 must be installed After installing the D45 IP interface Config 3 0 it can be run The interface is shown below Select the INTERFACE node at the left of the main interface and input the name of the D45 IP interface into the red box at the right The users can either input a name that can be easily remembered such as D45 IP...

Страница 56: ... DHCP server can dynamically distribute an IP address for the D45 IP interface Or you can select the Fixed IP mode which is a manual IP configuration mode In this mode the addresses can be configured manually n the IP address will be used to configure the IP address of item 323011 defaulted at 192 168 1 100 Please configure the IP address based on the actual system situation which is suggested as ...

Страница 57: ...f yes please select Yes if it s only used to connect the backbone select NO On selecting No the Lower address Higher address and system address range will become grey which means that they cannot be set The Lower address option is used to input in the lowest address range 0 to 3999 It must be smaller than the higher address that connects item 323011 to the handset The Higher address option is used...

Страница 58: ... for Backbone Main EP and EP may be different from that used for a floor shunt When using IT1 and the floor shunt the EP address range is 1 to 80 and so is the EP But when using 323011 and EP jointly use the same address section namely that main EP EP address range is 1 to 80 All the main EPs and EPs in the system are identified with line address from 1 to 80 that can t be repeated Example If the ...

Страница 59: ...anagement centre directed by the D45 IP interface which will be defaulted at 1 If the actual address of the management centre is not set to 1 it s recommended that it is 1 then you can modify and input in the actual address With several management centres you can add addresses by pressing the key and input in the correct ones By using the key you can sort an address list for the several management...

Страница 60: ...leting the above configuration press to save the configuration for future view or maintenance Press used for the download configuration Serialport ConnectionforUSBconfigurationdownload Connectionforserialportconfigurationdownload ConnectthecomputerUSBport ConnectthecomputerserialportorUSBtransfertotheserialportline ConnecttheEthernetport ConnectionforEthernetconfigurationdownload USB LAN SerialPor...

Страница 61: ...ick NEXT to go to the download configuration interface it will indicate either success or failure If serial port is selected for the configuration click NEXT As it can be seen in the following diagram select the port selection to manually specify the serial port number and select Detect Automatically to automatically detect the serial port It is not necessary to specify the serial port Then click ...

Страница 62: ...he following diagram if you click it will automatically find the USB connection Then click on NEXT to go to configuration download no password required It will indicate either success or failure Wiring options for the installation of item 323011 Other323011or346890 BT s2 wiresystemIPinterface 323005 323003 323011 323010 323010 Backbone main EP IfthemainEPisclosetotheD45 IPinterface thenanauxiliary...

Страница 63: ...ctor 30 Vdc 2 Output connector for riser system Floor shunt SUB SYSTEM IN interface 3 Empty not used 4 Input connector for riser system Floor shunt SUB SYSTEM OUT interface 5 Empty not used 6 Video gain adjust switch 7 Configuration connector for updating software and connect the PC in series Video gain setting instruction switch to left is ON switch to right is OFF The instruction data in above t...

Страница 64: ...23010 For more information please refer to chapter rules for using the power supply in the system 323005 Functions Loaded short circuit protection if the DC output suffers a short circuit the power supply will enter protection status and stop the voltage output After the problem is solves it will come back to normal automatically Smart power supply in system where various Small EP are connected wi...

Страница 65: ...udio impedance and supply power to communication cable OFF cut audio impedance and stop supply power to communication cable LEGEND 1 Battery 2 Switch ON OFF 3 AC IN 4 Protect Earth must be connected to earth ground 5 Power off red light on Power on green light on 6 Low voltage indicator red light on 7 Data audio video transmission 8 Data audio video and power transmission N L L E N 1 2 3 4 5 N L L...

Страница 66: ...er the configuration parameter press S2 the default parameter is 0 Increase by 1 with each pressure The CFG light will flash quickly twice The highest number possible is 9 5 Confirmtheconfigurationparameter pressS1 theCFGlight will flash quickly twice and then flash slowly twice Then the configuration procedure for this step is now completed 6 Set the next parameters if necessary set the other con...

Страница 67: ...ed it can be used as a Switchboard or main EP backbone expansion interface and can support several wiring methods LEGEND 1 S1 key 2 Power supply light indicator 3 Additional power supply connector DC30V 4 B1 interface connect the main EP or the Switchboard 5 B2 interface connect the main network 6 Connect WEP or Switchboard 7 Pushbutton configuration indication 8 S2 key 9 Software update and compu...

Страница 68: ...ation place CF1 CF2 CF3 CF4 CF5 CF6 MC min MC min MC max MC mac DEV DIR Meaning of the configuration place Configuration place Mode 1 Mode 2 Mode 3 CF1 Min Same as Mode 1 Same as Mode 1 CF2 CF3 Max CF4 CF5 DEV CF6 DIR Nota Min TheminimumnumberconnectedtotheBackbone mainEPorthe SwitchboardatmainEP Switchboardinterface Max ThemaximumnumberconnectedtotheBackbone mainEPorthe SwitchboardatmainEP Switch...

Страница 69: ... been successful the CFG will flash once and then come on steady The new configuration is now available If the procedure fails one configuration place is over the effective value like DEV 1 the CFG indicator will be off and the old configuration will be kept If the configuration value is logically wrong such as Min Max then on reset the CFG indicator will flash slowly indicating wrong configuratio...

Страница 70: ...ard shunt X X X X 1 1 X X X X 1 1 X X X X 0 1 X X X X 0 1 X X X X 0 1 X X X X 0 1 Connect the EP 323003 323005 323018 323001 323001 323018 323004 323001 323007 323001 323001 323018 323018 323018 323018 Connect Floor shunt Backbone mainEP Backbone mainEP Backbone mainEP Backbone mainEP Backbone mainEP System accessories functions overview 323013 ...

Страница 71: ...face to connect the HANDSET or the BTicino home system 2 POWER Power indication when the red indicator is on it means a normal power supply 3 S1 internal status indicator when it s on it means that the internal end of 346858 is engaged 4 S2 external status indicator when it s on it means that the external end of 346858 is engaged 5 Resistor configurator used to configure the setting parameters 6 E...

Страница 72: ...ferstotheaddressoftheSwitchboard withnoneedtoseton346858 relyingontheC placesettingontheRisershunt ExamplE 1 If the unit building relevant to 346858 has 18 floors 4 households on each floor then D45 system can use Mode 1 for the system configuration If the 346858 floor is 17 F and the second household then its configuration can be as follows ConfigURATION place Simple configuration Mode 1 CF1 FF 1...

Страница 73: ...ble 1 piece Directions for the Configuration tool Forthe detailsofhowtouse the 323020 disc software please refer to the instructions on the box the help document or the relevant sections in this manual Wiring method for the tool interface Wiring method 1 insert as per the arrow direction This method is mainly used to download the configuration information such as to download the configuration info...

Страница 74: ...ctionsasperthedigits Left maleconnector Right Femaleconnector Left Relevant connection as per the digits Right 1 1 2 2RX 3 3TX 4 4 5 5GND 6 6 7 7 8 8 9 9 Wiring method 2 Only for firmware specialist to upgrade It s only used to update the programs Most devices are updated in this way EP sfrontview System accessories functions overview ...

Страница 75: ...ALLATION RULES Entrance panels and indoor handsets installation 74 System cable 77 Standard RJ45 connections 78 Lock type and distance limits 81 Power supply installation rules 83 Power supply check and calculation 89 Maximum system limits 93 ...

Страница 76: ...installedataheightof 120 125cm RECOMMENDATION FOR THE INSTALLATION POSITION OF THE SMALL EP EP MAIN EP The most important condition to observe in the positioning of cameras is that they must not be turned towards light source for example lamps sunlight reflecting surfaces etc HANDSET INSTALLATION HEIGHT When installing audio or video internal units it is advisable to position the devices as indica...

Страница 77: ...ion 322010 installation method Note Theflushmountedboxmustbeorderedseparately Don tinstallinhotordampplaces InstalltheEPonthedoor Sizeoverview InstalltheEPonthewall 1 4 1 4 Flushmountedbox Rack Screw Flushmountedbox Rack Screw 1 4 1 4 325 mm 125 mm 60 5 mm ...

Страница 78: ...ble to EP clamps and fit the cover to the body using the two grooves on the top 3 Secure the cover in position 4 Tighten up the bottom screw Installation instructions 1 Fix the base to the flush mounted box using the vertical holes 2 Connect the cable to EP clamps and fit the cover to the body using the two grooves on the top 3 Secure the cover in position 4 Tighten up the bottom screw Don tinstal...

Страница 79: ... Ring 802 3 10BASE T Ethernet 802 3 100BASE T Ethernet CAT5e D 568 B 11801 2002 100 802 5 Token Ring 802 3 10BASE T Ethernet 802 3 100BASE T Ethernet 802 3 1000BASE T Ethernet BTicino recommend the use of its cable CAT 5 Details as follows CAT 5E U UTP CABLES U UTP SHEATH LENGTH PACKAGING 032750 LSZH 305 m BOX 032751 PVC 305 m BOX 032873 LSZH 1000 m COIL 032874 PVC 1000 m COIL Unshielded U UTP cat...

Страница 80: ... installation Table 1 shows the two standards PIN T568A T568B SIGNAL n pair wire colour pair wire colour 1 3 2 VIDEO 2 3 2 VIDEO 3 2 3 AUDIO 4 1 1 POWER 5 1 1 POWER 6 2 3 AUDIO 7 4 4 SCS 8 4 4 SCS The four pairs are identified with different colours and each pair carries a different type of signal see Table 1 Table1 87654321 12345678 Pair 1 Pair 3 Pair 2 Pair 4 Pair 1 Pair 2 Pair 3 Pair 4 T568A T5...

Страница 81: ... in order of colour Make sure the cable is free of crimps and is straightened Wire map 1 2 3 4 5 6 7 8 1 8 Colour White orange Orange White green Blue White blue Green White brown Brown SIGNAL Video Video Audio Power Power Audio Data Data RJ45 wire map and connection method Wirespecification CATcable Step 4 after Straightening out each wire and putting them in colour order check the order again Us...

Страница 82: ... the connector When squeezing a click sound should be heard The following picture shows a correctly fitted connector Step 8 test the cable Connect the two RJ45 connectors to the tester Turn on the test The two groups of lights will be flashing If the 8 lights turn to green one by one it means the cable is correctly assembled Any red lights or yellow lights indicate an open circuit or bad connectio...

Страница 83: ...ed for the door lock is more than 1A DC12V the use of an additional power supply is required instead of obtaining power from the EP The connection is shown below The door lock receives power from an additional power supply without absorbing any current from the EP In some cases other types of door locks may be used for EPs or main EP The main characteristic recommended for door locks are below Nee...

Страница 84: ...pply The power supply is the auxiliary EP power supply in some cases the riser has several EP In this case auxiliary power supply will be needed additional power supply is also needed if the main EP cable is too long The door lock accessory can be directly connected to this power supply without the need for an additional one Cabletype 2x1 0mm2 Cabletype 2x1 0mm2 Maxdistance 20m Maxdistance 250m EP...

Страница 85: ...ta communication cable and offer impedance matching for the audio channel at the same time Therefore In the project usually PWS smart power supply is used as system power only when the system needs auxiliary power supply with smart function the PWS will be set as auxiliary power supply otherwise the auxiliary power supply will be used Riser shunt Where system power supply is needed in D45 systems ...

Страница 86: ...sneededinthemainnetworkarea One323005isneededinthegreenareaoftheunit One323005isneededintheblueareaconnectedto 323019 LEGEND Unit 1 Unit3 Unit 2 Mainnetworkline Mainnetworkline 323002 handset handset handset handset 323002 handset handset handset handset 323002 handset handset handset handset 323019 323005 323005 323003 EP 323005 323005 Power supply installation rules ...

Страница 87: ... 1 None None 1 X X X X X X Under these four condition using auxiliary power supply no need configurate 2 None None 1 X X X X X X 3 have None 1 X X X X X X 4 have None 1 NNN X 1 0 2 9 1 X 5 None have 2 NNN 1 1 0 1 X X 2 1 0 1 X 6 None have 2 NNN 1 1 0 1 X X 2 1 0 1 X 7 have have 2 NNN 1 0 2 9 0 1 X X 2 0 2 9 0 1 X 8 have have 2 NNN 1 0 2 9 0 1 X X 2 0 2 9 0 1 X Note X Itmeansnoconfiguratorisneededa...

Страница 88: ... Audio connection Data connection Impedance switch 1 When there is no riser shunt in the system the system power supply should be connected and set as following drawing 2 When there is riser shunt in the system the system power supply should be connected and set as following drawing 323002 323002 EP 323005 B C A ON ON ON OFF Toriser SecondaryEP 323005 D A Backbone 323003 Powersupply 323005 Power s...

Страница 89: ...rom system BUS power supply The system BUS power supply should be connected and set as per the following drawing CONNECTION AND SETUP PROCEDURE FOR 323005 3 When there is no 323013 on the system BUS the system power supply on the BUS should be connected and set as per the following drawing ON SecondaryEP 323005 D A FromEPS 323013 323001 Backbone Backbone Backbone Backbone 323005 B C ON Backbone 32...

Страница 90: ...hed to off as per the following drawing 1 the connection of the auxiliary power supply inside the riser 2 When system Bus needs auxiliary power supply the connection should be as follows 3 When there is a Switchboard in the system the Switchboard will get power from the BUS system auxiliary power supply Connection should be as per the following drawing AuxiliaryPowersupply 323010 323005 D C A 3230...

Страница 91: ...rrent alarm sensor The maximum quantity of handsets and EP that the riser system power supply can accept TYPE OF HANDSETS 1 2 3 4 5 6 7 8 9 10 11 12 1 EP Riser shunt without A C 40 4 12 4 1 N 4 2 52 4 12 24 1 4 1 4 1 2 EP Riser shunt Entrance panel video mixer without A C 32 4 8 4 1 N 4 2 44 4 12 20 1 N 4 1 3 EP Riser shunt Entrance panel video mixer without A C 28 4 4 N N 4 2 38 4 8 12 1 N N 4 EP...

Страница 92: ...de power to riser shunt the Floor shunt and the handsets Maximum distance between EP or handset and power supply In the riser the quantity of devices managed by a power supply are shown in table 4 table 5 and table 6 Case 1 case 2 case 3 case 4 case 7 case 8 case 9 are for 323005 PW1 and 323010 aPW1 Case 4 case 5 case 6 case 10 case 11 case 12 are for 323005 PW1 Notes 1 The current can also be aff...

Страница 93: ...r 36 apartments floor 4 2 max 1 floor 8 2 max 1 floor 80 max 3 floors 8 max 1 floor Table 6 Case 9 to Case 12 the quantity of devices managed by 323005 Power supply How many apartments on every floor HANDSET Case 9 Case 10 Case 11 Case 12 Total Qty of handsets Floor limit Total Qty of handsets Floor limit Total Qty of handsets Floor limit Total Qty of handsets Floor limit 2 apartments floor Don t ...

Страница 94: ...Table 7 323010 application on case 4 case 5 case 6 case 10 case 11 and case 12 How many apartments on every floor HANDSET Case 4 Case 5 Case 6 Case 10 Case 11 Case 12 4 handsets floor 4 2 3 6 4 5 8 handsets floor 4 2 3 6 4 5 12 handsets floor 4 2 3 6 4 5 16 handsets floor 4 2 3 6 4 5 20 handsets floor 4 2 3 6 4 5 24 handsets floor 4 2 3 6 4 5 28 handsets floor 4 2 3 6 4 5 32 handsets floor 4 2 3 6...

Страница 95: ...k system 100 Riser shunt in the whole system IP network system 100 each IP area expandable District generator in the whole system non IP network system 5 Using level connection with 5 District generators it can expand 16 networking branch routes Switchboards in the whole system 16 Video limit distance Colour Video limit EP to HANDSET 1 Km B W Video limit EP to HANDSET 2 Km Most of items have the v...

Страница 96: ...3 Example for distance limits CASCADE INSTALLATION LIMITS OF VIDEO SIGNAL After being transmitted by multilevel cascade insert video amplifier video splitter etc in transmission channel the video signal will have distortion and the quality of the image will decrease In D45 the maximum level of cascade is 6 If any of the following devices is passed by a video signal in the system the cascade level ...

Страница 97: ...DEX 95 D45 VIDEO DOOR ENTRY SYSTEM CONFIGURATION RULES General configuration concept 96 Entrance panels configuration examples 99 Handsets configuration examples 101 Accessories configuration examples 103 ...

Страница 98: ...pick up Identify the apartment that issued the alarm send the alarm to the right Switchboard n Self powering of the right building main EP or secondary EP from apartment and Switchboard n Some devices of the system must be configured The configuration consists of two activities n Decide the right numbers to obtain the intended function a design project activity n Teach to the physical device its p...

Страница 99: ...progressive riser shunt address is used as the lowest two digits of DDDD no configuration of the apartment villa to call is needed in the Wall entrance panel or Switchboard If the customer want a complete DDDD address to call the apartment villa an association must be performed on the wall entrance panel and on the Switchboard between the riser shunt progressive address and the DDDD requested by t...

Страница 100: ...number is over 4000 Mode 2 must be considered 20 4 NO 20 4 NO 20 4 NO 2 Below is an example explaining the rules for system configuration Mode 2 For example if the highest building of a project has 25 floors and the max number of apartment for floor is 8 with 15 risers in total Then for mode 2 the FF should be 25 while II should be 8 Make the calculations according to following table to judge if m...

Страница 101: ...er of handsets per floor Configurators position for ep Example A EP address is 5 each riser has 20 floors and each floor has 4 handset system configuration mode 1 is used The Switchboard directly connected to the main EP is no 2 main EP configuration should be as follows Position Value for configurator RemarkS N 0 0 N 5 F FF is 20 default No need for configuration F I II is 4 default No need for c...

Страница 102: ...is ok not to insert configurator 0 N 5 F 2 F 2 I 0 It is ok not to insert configurator 0 I 8 NOTE thereisanadditionalconfigurationslot M M switchboardaddressnumber canbesetonlybykeyboardorbySF2software N N F F I I 0 5 2 5 0 8 EP configuration examples 322010 Digital Entrance Panel configuration If configurator or keyboard configuration is selected for the main EP the following conditions must be m...

Страница 103: ...e value for all system handsets I FF Handset floor number II handset household number II typical number of handsets per floor Example A The number of handsets is 1204 each floor has 4 handsets the system configuration mode is Mode 1 the handset configuration should be as follows Position configuration value RemarkS F 1 F 2 I 0 It is ok not to insert configurator 0 I 4 I Because the default value o...

Страница 104: ... 8 handsets System configuration mode 2 is used The handset configuration should be as follows Position value RemarkS F 1 F 2 I 0 It is ok not to insert configurator 0 I 6 I 0 It is ok not to insert configurator 0 I 8 b F F I I I I 1 2 0 6 0 8 321010 HANDSET CONFIGURATION Handset configuration examples ...

Страница 105: ... CF2 CF3 CF4 CF5 CF6 CF7 CF8 C M N N N N F F I I C M ON SD 1 2 3 4 ON SD 1 2 3 4 Accessory configuration examples C the Switchboard number that is the first priority for this riser If the number of the Switchboard is more than 9 from 10 to 15 this parameter can only be set using the riser shunt keyboard or the system configuration software tool M System configuration mode If the selected configura...

Страница 106: ...uration should be as follows Position Mode 1 Value for configurator RemarkS CF1 N 0 0 no config needed CF2 N 0 0 no config needed CF3 N 0 0 no config needed CF4 N 5 CF5 F FF is 20 default No need for configuration CF6 F CF7 I II is 4 default No need for configuration CF8 I C C 2 M M 0 0 no config needed A CF1 CF2 CF3 CF4 CF5 CF6 CF7 CF8 C M N N N N F F I I C M 0 0 0 5 2 0 ON SD 1 2 3 4 ON SD 1 2 3...

Страница 107: ...lled directly by this riser is no 2 System configuration mode 2 is used The riser shunt configuration should be as follows Position Mode 1 Value for config RemarkS CF1 N 0 It is ok not to insert configurator 0 CF2 N 0 It is ok not to insert configurator 0 CF3 N 0 It is ok not to insert configurator 0 CF4 N 5 CF5 F 2 CF6 F 5 CF7 I 0 It is ok not to insert configurator 0 CF8 I 8 C C 0 It is ok not t...

Страница 108: ...er The main EP QTY and EP total quantity for all risers cannot exceed 80 This means that the total quantity of riser EP main EP 80 Example If D45 should be compatible with the BT system there are two D45 IP interfaces used in system First D45 IP interface 1 to connect 2 main EP and 3 cells Cell 1 2 3 each cell has one EP second D45 IP interface 2 to connect 0 main EP and 3 cells cell 4 5 6 cell 4 ...

Страница 109: ...stor configuration method Not inserting the configurator resistor the value will regard as 0 Pushbutton ON method RS232 method Remarks When using item 323009 the room number is configured automatically no need to set it at the handset Press Mode 1 and Mode 2 to select the desired configuration method The user can select any method based on system complexity and structure When the phisical configur...

Страница 110: ...rwise use mode 2 for the configuration Example Note TheconfigurationvalueinthefollowingexamplecanbeconfiguredwitheithertheconfiguratororserialRS232 n A Apartment interface There are 20 floors in the 323009 unit with four houses on each floor When the house number is 1204 323009 can be configured as per Mode 1 Configuration place Configuration value Remarks Configuration diagrams CF1 1 FF 12 F F I ...

Страница 111: ...uration value is bigger than 9 the CFG indicator will go off and then come back on using the old configuration If the configuration value is logically wrong such as II II then on reset the CFG indicator will flash quickly indicating wrong configuration and pushbutton operation will stop In this case connect the non zero 1 to 9 resistor to the configurator and repower to clear all the values config...

Страница 112: ...ration Use RS232 configuration configuratorS position for EP switchboard shunt CF1 CF2 CF3 CF4 CF5 CF6 MIN MIN MAX MAX DEV DIR 0 4 0 5 0 0 Position Mode 1 Value for config Remark CF1 MIN 0 x CF2 MIN 4 x CF3 MAX 0 x CF4 MAX 5 x CF5 DEV 0 x CF6 DIR 0 x The 323018 used to extend one switchboard switchboard address range is 4 to 5 all main EP are installed in the B2 port of 323018 configuration as fol...

Страница 113: ... CF5 CF6 MIN MIN MAX MAX DEV DIR 0 4 0 4 0 1 CF1 CF2 CF3 CF4 CF5 CF6 MIN MIN MAX MAX DEV DIR 0 4 0 5 1 0 Example A Item 323018 is used to extend one Switchboard The Switchboard address range is 4 all main EP are installed in the B1 port of 323018 configuration as follows Example B Item 323018 used to extend the main EP The main EP address range is 4 to 5 all Switchboards are installed in the B1 po...

Страница 114: ...F4 MAX 5 x CF5 DEV 1 x CF6 DIR 1 x C CF1 CF2 CF3 CF4 CF5 CF6 MIN MIN MAX MAX DEV DIR 0 4 0 5 1 1 323018 EP Switchboardshuntconfiguration Example C Item323018isusedtoextendoneSwitchboard Switchboard address range is 4 all main EP are installed in the B1 port of 323018 configuration as follows Accessory configuration examples ...

Страница 115: ... to configure NNN FF Min the floor number where this power management starts from FF Max the floor number where this power management ends FF Max must over or equal to FF Min II number of apartments on each floor at mode 1 the default number is 4 no need to set Min handset the address of the first address managed by this power supply Max handset the last handset address managed by this Power suppl...

Страница 116: ...NKING RESERVE OF EACH APARTMENT SUPPLIED BY THE PS 0 300 mA Default Max 1 0 mA 2 50 mA 3 85 mA 4 120 mA 5 150 mA 6 180 mA 7 210 mA 8 240 mA 9 270 mA LE configuration position for smart power supply function This position controls when to enter energy saving mode under different situations 0 AC is not an not energy saving 1 AC is not an not energy saving NOT energy saving all the system functions a...

Страница 117: ...oors If necessary enable the smart power function and the power management function the power supply address is 12 max current of the alarm sensor is 300 mA System configuration mode 2 is used The power supply configuration should be as follows Position Mode 1 Value for configurator RemarkS CF1 N 0 CF2 N 1 CF3 N 2 CF4 FF Min 0 CF5 FF Min 1 CF6 II 0 CF7 II 5 CF8 FF Max 0 CF9 FF Max 2 CF10 CF10 Here...

Страница 118: ... function the power supply address does not need to be set the range of handset addresses managed by the power supply is 125 163 Without alarm it means that the current of alarm sensor is 0 mA The system used mode 3 configuration The power supply configuration should be as follows Position Mode 1 Value for configurator Remarks CF1 N 0 CF2 N 0 CF3 N 0 CF4 FF Min 0 CF5 FF Min 1 CF6 II 2 CF7 II 5 CF8...

Страница 119: ...ted configuration No system PWS Solution CONFIGURATION WHEN PWS IS SYSTEM POWER SUPPLY IMPEDANCE SWITCH OF PWS MUST BE ON CONFIGURATION OF PWS AND AUXILIARY PWS WHEN PWS IS AUXILIARY POWER SUPPLY IMPEDANCE SWITCH OF POWER SUPPLY MUST BE OFF Alarm Small EP CF1 CF3 NNN CF4 CF11 CF12 Type CF13 ASR CF14 M CF15 LE CF1 CF3 NNN CF4 CF11 CF12 Type CF13 ASR CF14 M CF15 LE 1 No No 1 X X X X X X Here use Aux...

Страница 120: ...for District generator EPS EPS MC Min MC Min MC Max MC Max P S CF8 CF9 CF10 EPS EPS Min Min MAXMAX P S Position Mode 1 CF1 EPS If 323013 is primary EPS must be set as MaxWEP address onWEP port If 323013 is secondary EPS must be set as MaxWEP address on MC port CF2 CF3 MC Min Set Switchboard address range CF4 CF5 MC Max CF6 CF7 P S 0 primary 323013 1 secondary 323013 MEANING OF EACH CONFIGURATOR SO...

Страница 121: ...e sure that main EP number on main EP port of first DG layer main EP number in first DG layer branch main EP number in second DG layer branch 323013 District generator configuration 323013 323013 323013 323013 Switchboard 323010 323005 323010 Backbone mainEP Secondary DistriCT GENERATOR PRIMARY DistriCT GENERATOR 323003 323003 323003 323003 323013 323003 323003 323003 323003 ...

Страница 122: ...ress on MC port 323013 323013 323013 323013 Switchboard 323010 323005 323010 323004 Backbone mainEP Backbone mainEP 323013 323003 323003 323003 323003 323003 323003 323003 323003 323004 Backbone mainEP Backbone mainEP PRIMARY BACKBONE MAIN ENTRANCE PANEL SECONDARY BACKBONE MAIN ENTRANCE PANEL 323013 District generator configuration Accessory configuration examples ...

Страница 123: ...e Position Field Name 1 DistricT generator 2 DistricT generator 3 DistricT generator Remarks CF1 EPS 0 0 0 NULL means 0 CF2 1 2 8 CF3 MC Min 0 0 0 CF4 0 0 0 CF5 MC Max 0 0 0 CF6 0 0 0 CF7 P S 0 1 1 323013 2 323013 323013 323013 1 323010 323010 323005 323013 3 323003 323003 323018 323018 323018 323018 Backbone mainEP 1 Switchboard 0 323003 323003 Backbone mainEP 2 Backbone mainEP 8 Switchboard 2 Sw...

Страница 124: ...fist District generator layer branch to install the main EP and Switchboard Some second District generator layer branch could be extended to install the main EP and Switchboard also using the EP Switchboard shunt Below diagram 1 3 District generator configuration example Switchboard 6 Backbone mainEP 8 323013 2 323013 323013 323013 1 323010 323010 323005 323013 3 323003 323018 323003 323018 323018...

Страница 125: ...e EP Switchboard shunt to extend the branch of the second DH1 layer to install WEP and Switchboard Below diagram 1 3 DH1 configuration as an example Switchboard 6 Switchboard 6 Backbone mainEP 8 Backbone mainEP 8 323013 2 323013 323013 323013 1 323010 323010 323005 323013 3 323018 323003 Backbone mainEP 1 Switchboard 0 323003 323018 323018 323003 323003 323018 323013 District generator Secondary D...

Страница 126: ...t does it means that the riser shunt is set incorrectly 7 The entrance panel fails to call a certain handset The handset number may be set incorrectly in which case reset the number and try again If the call still fails Troubleshooting set the number as 101 and try again If it is successful it may be that the handset household on each floor is not the same as the II setting on the entrance panel R...

Страница 127: ...n unclear about which parameter is incorrect it is recommended to reset the default parameters and start again Note afterthedefaultparameterhasbeenrestored alltheotherparameterswillbe restoredtotheex factoryvalue 16 The alarm indicators or the zone indicators are always on irrespective of the status This results from the overcurrent of the alarm probe powered by the handset which automatically cau...

Страница 128: ......

Страница 129: ...ict generator 129 6 Riser with mixed installation 130 7 Internal unit connection 131 8 Connection between audio and video handset 131 9 BTicino 2 wire interface connection 131 10 11 Basic apartment interface 131 12 Riser with several EPs without riser shunt 132 13 14 Backbone with several main EPs 132 15 Riser with more than 5 EPs 134 16 2 branches video splitter connection 135 17 Riser with syste...

Страница 130: ...oor 2 FLOOR n 1 Floor N OTHER FLOOR 323002 handset handset handset handset 323002 handset handset handset handset 323005 EP 323010 ENTRANCE Floor 1 Floor 2 FLOOR n 1 Floor N OTHER FLOOR 323002 handset handset handset handset 323002 handset handset handset handset EP 323010 323003 323003 323003 323005 323005 Backbone Backbone mainEP Porter Switchboard 323003 323003 323003 323003 323003 323005 32300...

Страница 131: ...129 D45 VIDEO DOOR ENTRY SYSTEM EXAMPLE 5 backbone with District generatOR 323003 323003 323003 323003 323003 323003 323003 323003 323013 323010 323010 323005 Backbone mainEP Porter Switchboard ...

Страница 132: ...ailable It is depended on the backbone system and final products ENTRANCE Floor 1 Floor 3 Floor 2 OTHER FLOOR 323002 handset handset handset 323002 handset handset handset handset EP 323010 323005 346858 323002 handset handset handset handset Backbone MyHome Device 323010 323008 handset handset Secondary EP 323003 Slave Slave MASTER System layout examples ...

Страница 133: ... EP only can call the master handset for conversation and door lock release n All handsets will ring and the display of the master handset will come on After the call is answered the display on the handset answering the call will come on and the other handsets will stop ringing n The master handset can monitor the Small EP Remarks n When the total power consumption for all handsets connected to 32...

Страница 134: ... 12 RISER WITH SEVERAL EP WITHOUT RISER SHUNT 323002 323005 Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP 323004 Backbone mainEP Backbone mainEP Backbone mainEP Backbone mainEP Backbone mainEP 323005 Backbone 323003 323004 323010 323010 323010 323010 323010 System layout examples ...

Страница 135: ...RY SYSTEM example 14 BACKBONE WITH SEVERAL MAIN EPS Backbone mainEP Backbone mainEP Backbone mainEP Backbone mainEP Backbone mainEP 323005 323013 323005 Backbone Backbone Switchboard 323004 323010 323010 323010 323010 323010 ...

Страница 136: ...ry EP Secondary EP Secondary EP Secondary EP 323004 Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP 323004 Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP 323004 Secondary EP Secondary EP Secondary EP Secondary EP Secondary EP 323004 System layout examples ...

Страница 137: ...HE NUMBER OF HANDSETS ENTRANCE Floor 1 Floor 2 FLOOR n Floor N 1 OTHER FLOOR 323002 handset handset handset handset 323002 handset handset handset handset EP 323019 323005 Backbone 323003 323005 Floor 2 FLOOR n 323002 handset handset handset handset 323002 handset handset handset handset 323007 ENTRANCE Floor 1 EP Backbone 323003 323005 ...

Страница 138: ......

Страница 139: ...connections with several EPs 2 142 6 Backbone connection with 1 main EP 143 7 Backbone connection with 1 switchboard 144 8 Backbone connection with several EPs 145 9 District generator connection 146 10 2 layer DG connection 147 11 2 layer DG with several EPs 148 12 Riser with video mixer 149 13 Riser with 2 branches video splitter 150 14 Riser with expansion interface 151 15 Internal unit alarm s...

Страница 140: ...ANDSET BASIC CONNECTIONS ALARMSENSORS 323002 323015 SmallEP Handset Normallyastandard0 5mm2 cablecanbeused dependingonsensortypeandinstallationdistance Forvideosignalsastandardcablecanbeused Fordatasignalsusea0 5mm2 cable inaccordancewithinstallationdistances Adaptor 15 V 2 A ...

Страница 141: ...total power consumption for all handsets connected to 323008 exceeds the limit an auxiliary power supply 323010 is required DIAGRAM 2 323008 basic apartment interface connection handset handset handset handset handset 323010 323002 323008 323008 handset ...

Страница 142: ...AMs D45 DIAGRAM 3 riser handsets connection with floor shunt 323002 Wiring diagrams HANDSET HANDSET HANDSET 323002 323002 323002 323005 323010 HANDSET HANDSET HANDSET HANDSET HANDSET HANDSET HANDSET HANDSET HANDSET Tonext FloorShunt323002 EP ...

Страница 143: ...141 D45 VIDEO DOOR ENTRY SYSTEM DIAGRAM 4 RISER CONNECTION WITH SEVERAL EPS EXAMPLE 1 323002 Tonext FloorShunt323002 HANDSET HANDSET HANDSET 323005 HANDSET EP EP EP EP EP 323004 ...

Страница 144: ...IDEO DOOR ENTRY SYSTEM WIRING DIAGRAMs D45 DIAGRAM 5 RISER CONNECTION WITH SEVERAL EPS EXAMPLE 2 Wiring diagrams EP EP EP To FloorShunt323002 ToRiserShunt323003 323003 323005 323004 ToRiserShunt323003 EP EP ...

Страница 145: ...RAM 6 Backbone connection with 1 main EP Tonext FloorShunt323002 323002 HANDSET HANDSET HANDSET 323005 323005 323005 323005 323003 323003 323003 HANDSET Tonext RiserShunt323003 To Floor Shunt 323002 To Floor Shunt 323002 To EP To EP EP EP ...

Страница 146: ...KBONE CONNECTION WITH 1 SWITCHBOARD Wiring diagrams Tonext FloorShunt323002 323002 HANDSET HANDSET HANDSET 323005 323001 323005 323005 323005 323003 323003 323003 EP HANDSET Tonext RiserShunt323003 To PE EP To Floor Shunt 323002 To EP To EP To Floor Shunt 323002 ...

Страница 147: ...NECTION WITH SEVERAL MAIN EPS To Floor Shunt 323002 To Floor Shunt 323002 To Floor Shunt 323002 To EP To EP To EP 323003 323003 323005 323010 323010 323010 323010 323010 323005 323005 323005 323003 323004 Tonext RiserShunt323003 BackbonemainEP EP EP EP EP ...

Страница 148: ...s 323003 323003 323005 323005 323013 323001 323005 323005 323005 323005 323005 323003 323003 Riser Block 2 Riser Block 3 To Floor Shunt 323002 To Floor Shunt 323002 To Floor Shunt 323002 To Floor Shunt 323002 To EP To EP To EP To EP Riser Block 1 Riser Block 4 Tonext RiserShunt323003 Tonext RiserShunt323003 EP ...

Страница 149: ...oRisersblock2 ToRisersblock14 ToRisersblock10 ToRisersblock7 ToRisersblock3 ToRisersblock15 ToRisersblock11 323013 323013 323013 323013 ToRisersblock50 ToRisersblock10 ToRisersblock130 ToRisersblock90 ToRisersblock8 ToRisersblock4 ToRisersblock16 ToRisersblock12 323013 323010 323010 323010 323001 EP ...

Страница 150: ...AGRAMs D45 DIAGRAM 11 2 LAYER DISTRICT GENERATOR WITH SEVERAL EP CONNECTIONS Wiring diagrams ToRisersblock2 ToRisersblock3 323013 323010 323010 323010 323010 323010 323010 323005 323004 ToRisersblock10 ToRisersblock4 323001 EP EP EP EP EP ...

Страница 151: ...149 D45 VIDEO DOOR ENTRY SYSTEM DIAGRAM 12 riser with 323004 video mixer 323004 323010 323004 323004 323010 To RiserShunt323003 ToEP ToEP ToEP ToEP ToEP ToEP ToEP ToEP EP EP ...

Страница 152: ... riser with 2 branches video splitter 323007 Wiring diagrams Toother RiserShunt323003 Toother RiserShunt323003 Tonext RiserShunt323002 Tonext RiserShunt323002 handset 323002 323002 323007 323003 EP handset handset handset handset handset handset handset 323005 ...

Страница 153: ...xpansion interface 323019 To FloorShunt323002 HANDSET HANDSET HANDSET HANDSET HANDSET HANDSET HANDSET 323005 323019 323002 HANDSET 323003 323001 EP Toother RiserShunt323003 Toother RiserShunt323003 400IUs Numberofhandsets extendedfrom400to800 Floor2 Floorn ...

Страница 154: ...cednearthesensor IUcanaffordsensor12Vdc 300mAmax type Connection way for NC and NO contacts sensor 8 sensor 7 sensor 6 sensor 5 gas sensor smoke sensor door sensor infrared sensor 10 K 10 K NO C NC 12 V GND 12 V F1 GND F8 F7 F6 F5 F4 F3 F2 10 K 10 K Fn GND NC C 10 K 10 K Fn GND NC C NC C 10 K 10 K Fn GND NO C NO C 10 K 10 K Fn GND NO C sensor 8 sensor 7 sensor 6 sensor 5 gas sensor smoke sensor do...

Страница 155: ......

Страница 156: ...cino S p A reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same BTicino SpA Via Messina 38 20154 Milano Italia www bticino com A Group Brand D45 ...