2-55
Confidential
■
The entire image is dark
<User Check>
- Check whether the paper type setting is correct.
Step
Cause
Solution
1
Maintenance unit stained
Clean the Maintenance unit.
(Refer to
Section 4.3.2 in this chapter
)
2
The head property value is
incorrect or head calibration
has not been performed
Enter the head property value.
(Refer to
3
Head calibration not performed Perform head calibration.
(Refer to
4
Carriage PCB defective
Replace the Carriage PCB ASSY.
5
Maintenance unit defective
Replace the Maintenance unit.
6
Head defective
Replace the Head/carriage unit.
7
Main PCB defective
Replace the Main PCB ASSY.