2-30
Confidential
■
Error Code 42
Head voltage does not turn OFF.
<User Check>
- This may occur when the surrounding temperature is low. Increase the surrounding
temperature before use.
■
Error Code 43
Head thermistor problem
When the power was turned on, the head thermistor detected a temperature of -20
degrees centigrade or lower, or 80 degrees centigrade or higher.
Unable to print 42
LCD
Step
Cause
Solution
1
Head flat cable connection
failure
Reconnect the Head flat cable.
2
Carriage flat cable connection
failure
Reconnect the Carriage flat cable.
3
Carriage PCB defective
Replace the Carriage PCB ASSY.
4
Head defective
Replace the Head/carriage unit.
5
Power supply PCB defective
Replace the Power supply PCB ASSY.
6
Main PCB defective
Replace the Main PCB ASSY.
Unable to print 43
LCD
Step
Cause
Solution
1
Carriage flat cable connection
failure
Reconnect the Carriage flat cable.
2
Carriage PCB defective
Replace the Carriage PCB ASSY.
3
Head defective
Replace the Head/carriage unit.
4
Main PCB defective
Replace the Main PCB ASSY.
Содержание DCP Series
Страница 111: ...3 3 Confidential 2 PACKING For Ink Cartridge Model 3_002L ...
Страница 112: ...3 4 Confidential For Ink Tank Model 3_002L 1 ...
Страница 119: ...3 11 Confidential 2 CIS flat cable 3_006L CIS flat cable Cable guide Cable guide Flat core ...
Страница 231: ...5 9 Confidential Print Pattern for Creating Head Calibration Data Fit this mark on the left rear of the document cover ...
Страница 234: ...5 12 Confidential Scanning Compensation Data List ...
Страница 236: ...5 14 Confidential Test Pattern ...
Страница 240: ...5 18 Confidential Configuration List ...
Страница 256: ...5 34 Confidential pfadj1 Pattern pfadj2 Pattern ...
Страница 264: ...5 42 Confidential Margin Check Pattern ...
Страница 294: ...6 3 Confidential Power supply PCB 100 V series ...
Страница 295: ...6 4 Confidential Power supply PCB 200 V series ...
Страница 309: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...