2-29
Confidential
■
Error Code 3F
Carriage motor cannot stop.
<User Check>
- Release the release lever at the back of the Paper tray and remove the jammed
recording paper from the Engine part.
■
Error Code 40
Casing internal thermistor problem
When the power was turned on, the casing internal thermistor detected a temperature of
-20 degrees centigrade or lower, or 80 degrees centigrade or higher.
Unable to print 3F
LCD
Step
Cause
Solution
1
Carriage motor harness
connection failure
Reconnect the Carriage motor harness.
2
CR encoder strip stained
Clean the CR encoder strip.
3
CR encoder strip defective
Replace the CR encoder strip.
4
CR encoder sensor defective
Replace the Carriage PCB ASSY.
5
Carriage motor defective
Replace the Carriage motor ASSY.
6
Main PCB defective
Replace the Main PCB ASSY.
Unable to print 40
LCD
Step
Cause
Solution
1
Casing internal thermistor
harness connection failure
Reconnect the Casing internal thermistor
harness.
2
Casing internal thermistor
defective
Replace the Ink refill ASSY.
3
Main PCB defective
Replace the Main PCB ASSY.
Содержание DCP Series
Страница 111: ...3 3 Confidential 2 PACKING For Ink Cartridge Model 3_002L ...
Страница 112: ...3 4 Confidential For Ink Tank Model 3_002L 1 ...
Страница 119: ...3 11 Confidential 2 CIS flat cable 3_006L CIS flat cable Cable guide Cable guide Flat core ...
Страница 231: ...5 9 Confidential Print Pattern for Creating Head Calibration Data Fit this mark on the left rear of the document cover ...
Страница 234: ...5 12 Confidential Scanning Compensation Data List ...
Страница 236: ...5 14 Confidential Test Pattern ...
Страница 240: ...5 18 Confidential Configuration List ...
Страница 256: ...5 34 Confidential pfadj1 Pattern pfadj2 Pattern ...
Страница 264: ...5 42 Confidential Margin Check Pattern ...
Страница 294: ...6 3 Confidential Power supply PCB 100 V series ...
Страница 295: ...6 4 Confidential Power supply PCB 200 V series ...
Страница 309: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...