2-70
Confidential
4.8
Scanned-image Problems
4.8.1
Defective images
4.8.2
Scanned-image Problems
■
The entire image is light
<User Check>
- Check if the contrast is set to "Light".
- Clean the document cover glass or ADF glass.
- Clean the Document pressure bar.
Step
Cause
Solution
1
White level correction data
failure
Carry out maintenance 55.
2
CIS unit defective
Replace the CIS unit.
3
Main PCB defective
Replace the Main PCB ASSY.