Atmospheric Single-Arm Robot
Installation
User’s Manual
Connecting the Robot and Controller
Brooks Automation
Revision 1
3-13
8.
Manually move the robot to the 0,0,0 position. In this position the Z axis is
within 0.3 inch from the negative hard stop. The T axis is within 10° of the neg-
ative hard stop when turned in a clockwise direction. R-axis links are centered
over each other.
Facilities Connections
The standard configuration of the Atmospheric Single-Arm Robot requires vacuum,
communications, and electrical connections. Refer to the Facilities Requirements on
page 3-2
for specifications.
DANGER
All facilities being supplied to the product must be disconnected per
the facilities’ lockout/tagout procedures before servicing to prevent
the risk of personal injury or damage to the product.
CAUTION
Safety glasses should be worn at all times when connecting any facil-
ities to the product.
Electrical
CAUTION
Do not connect the product’s power supply to facility power
until all installation procedures have been completed.
Connect the power cable. This should be to a customer system that is monitored with
interlocks and an EMO system.
Vacuum
Connect the vacuum line from the system that the robot is mounted in to the Atmo-
spheric Single-Arm Robot.