![Brooks ABM 100 Скачать руководство пользователя страница 192](http://html1.mh-extra.com/html/brooks/abm-100/abm-100_user-manual_2818768192.webp)
Atmospheric Single-Arm Robot
Troubleshooting
User’s Manual
Troubleshooting Robot Start up
Brooks Automation
Revision 1
10-3
Troubleshooting Robot Start up
This procedure helps to troubleshoot problems at start up. Typical problems and
error codes that you may see include:
•
Robot will not start up
•
The robot will not home
•
The robot will not servo on
In these circumstances perform an aftermath analysis. The form for this is located in
Aftermath Analysis on page 10-29
Robot Start Up Procedure.
Table 10-1: Stat for Robot Will Not Start Up Flow Chart
BIT
Definition (When set to 1)
Cleared by
0
Previous command not executed
Any
1
Previous command invalid
Any
2
Vacuum Sensor is activated
3
Vacuum Switch is on
4
Motor error on one or more axes
SVON
5
One or more limit switches triggered
RLS
6
One or more axes are not homed yet
HOME A
7
Error on last alignment
ALIGN
8
Running Macro
9
One or more axes are moving
10
Servo off on one or more axes
SVON
11
Error on COM2
AST 2
12
Not used (always 1)
13
NV-SRAM error
RNCS
14
Controller error
Any
15
Error on COM1
AST 1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com