Table 10-2: Input G for Robot Will Not Start Up Flow Chart
BIT
Definition
0
Amplifier Interconnection and Signal Cable Closed Loop
1
EMO
2
Stop Signal
3
Amplifier Board Under Power. Low if OK
4
Motor Power Supply indicator. Low if on
5
Robot Interface Power Supply indicator. Low if powered
6
Switcher indicator. Low if Switcher is on
7
Bus Power indicator. Low if all voltages are good
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com