Test 1: NVS-Ram Test
The NVS-Ram (
N
on
V
olatile
S
tatic
Ram
) test displays the status of various files in the
controller. The status can be OK, BAD or Not Open
If all files and NVS-Ram are OK, click on the OK button to return to the Diagnostic
main menu.
If a file status is BAD or Not Open, download that file. Return to the Terminal mode
window and press the Download button.
If the NVS-Ram status is BAD, re-initialize NVSRAM and then download all the files
by accessing the Format NVSRAM dialog.
Figure 9-5: NVS-RAM Window