![Brooks ABM 100 Скачать руководство пользователя страница 213](http://html1.mh-extra.com/html/brooks/abm-100/abm-100_user-manual_2818768213.webp)
Troubleshooting
Atmospheric Single-Arm Robot
Using the
GLST
Command
User’s Manual
Brooks Automation
10-24
Revision 1
For a Robot-Only system in earlier firmware
, the Galil board controls three axes, T,
R, and Z. The 16-bit word response to the
GLST
command is defined in the following
table.
24
25
26
27
T axis servo off
R axis servo off
Z axis servo off
Track W axis servo off (4)
1-axis pre-aligner W servo off (4)
Flipper W axis servo off (4)
Flipper W axis servo off (8)
T axis servo off
R axis servo off
Z axis servo off
Track t axis servo off (4)
1-axis pre-aligner t servo off (4)
Flipper t axis servo off (4)
Flipper W axis servo off (8)
28
29
30
31
t axis servo off
r axis servo off
z axis servo off
Track w axis servo off (8)
t axis servo off
r axis servo off
z axis servo off
Track w axis servo off (8)
Table 10-12:
GLST
Command Response for Firmware Earlier that 6.0
Bit
Meaning when bit is set to 1 in pre-6.0 firmware
0
1
2
3
Read/write timeout
Responds with an error
Board is in debug mode
Galil command error
4
5
6
7
Reserved
Position error on robot T axis
Position error on robot R axis
Position error on robot Z axis
8
9
10
11
Robot T axis motion complete
Robot R axis motion complete
Robot Z axis motion complete
Robot T-axis servo off
12
13
14
15
Robot R-axis servo off
Robot Z-axis servo off
Reserved
Reserved
Table 10-11: Response to the GLST Command in 6.0+ Compared to Earlier Versions
Bit
Meaning when bit is set to 1 in 6.0+
firmware
Meaning when bit is set to 1 in earlier
firmware
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com