53
Service Manual
Singular Combi Boiler - BTC 439002301 A (12.2021)
EB Error - Temperature Resistance Check
1. Check if the resistance matches the temperature on the following
temperature resistance table.
—
86 °F: 40 kΩ
—
140 °F: 12.4 kΩ
—
185 °F: 3.9 kΩ
Figure 82
KΩ