![Bosch Rexroth IndraDrive Mi Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/bosch/rexroth-indradrive-mi/rexroth-indradrive-mi_project-planning-manual_40585070.webp)
Description
Symbol
Unit
KSM02.1
B-041C-
42N-__-
__0
KSM02.1
B-061C-
35N-__-
__0
KSM02.1
B-061C-
61N-__-
__0
KSM02.1
B-071C-
24N-__-
__0
KSM02.1
B-071C-
35N-__-
__0
KSM02.1
B-076C-
35N-__-
__0
Continuous torque at standstill
60 K
M
0_60
Nm
2.2
6.0
5.5
10.5
10.0
8.7
Maximum torque
M
max
Nm
9.4
25.0
18.0
35.0
28.0
29.0
Maximum current
I
max(rms)
A
6.8
14.9
17.7
Torque constant at 20 °C
K
M_N
Nm/A
1.60
2.03
1.16
2.52
1.85
Voltage constant at 20 °C
7)
K
EMK_1000
V/1000
min-1
98.2
125.0
71.5
155.0
114.0
113.8
Rotor inertia
J
rot
kg*m
2
0.00017
0.00087
0.00173
0.00430
Thermal time constant
T
th
min
13
18
15
25
Maximum speed (electrical)
n
max el
min
-1
5500
4300
6000
3400
4700
Thermal class (EN 60034‑1)
T.CL.
155
Last modification: 2013-12-16
1)
According to DIN EN ISO 11205; comparative value at dis‐
tance 1 m, out of cabinet; HCS types with order code -L***:
load-dependent
2)
Observe supply voltage for motor holding brakes
3)
See information on "Rated power consumption control voltage
input at U
N3
"
4)
Plus dissipation of braking resistor and control section
5)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
6)
Also depending on firmware and control section; see parame‐
ter description "P‑0‑0001, Switching frequency of power output
stage"; see "P-0-4058, Amplifier type data"
7)
Manufacturing tolerance ±5%
Tab. 5-2:
KSM without motor holding brake - Technical data
Rated power consumption control voltage input at U
N3
Plus power consumption of externally connected inputs/outputs,
plus safety option
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
68/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Technical data of the components