![Bosch Rexroth IndraDrive Mi Скачать руководство пользователя страница 309](http://html.mh-extra.com/html/bosch/rexroth-indradrive-mi/rexroth-indradrive-mi_project-planning-manual_40585309.webp)
sercos III
LED: Color / flashing pattern
1)
Description
Prio
2)
Off
NRT mode (no sercos communication)
3)
6
Permanently lit orange
CP0 (communication phase 0 active)
6
Flashing orange-green
CP1 (communication phase 1 active)
6
Flashing orange-green
CP2 (communication phase 2 active)
6
Flashing orange-green
CP3 (communication phase 3 active)
6
Permanently lit green
CP4 (communication phase 4 active)
6
Flashing green
Transition from Fast forward to Loopback
5
Flashing red-orange
Application error
(Sub-device/device error [C1D])
4
Flashing red-green
MST warning
4)
(S-0-1045, sercos: Device Status [S-Dev], bit15)
3
Permanently lit red
Communication error
(Sub-device/device error [C1D])
2
Flashing orange
Identification
(S-0-1044, sercos: Device Control [C-Dev], bit15)
1
Flashing red
Internal watchdog
0
1)
Flashing pattern: One square corresponds to a duration of
250 ms; the arrow marks the end of a cycle; abbreviations on
the squares: GN = LED permanently lit green, OG = LED per‐
manently lit orange, RD = LED permanently lit red, -- = LED is
off
2)
Display priority (1 = highest priority); the state of the highest
priority is displayed
3)
NRT = None Real Time
4)
MST = Master synchronization telegram
Tab. 11-8:
Diagnostic LED
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
307/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Commissioning, operation, diagnostics and maintenance
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01