6.5.6
XG8, analog motor encoder connection
Description
For encoders with a supply voltage of 5 Volt (max. 300 mA) and 12 Volt
(max. 60 mA):
HIPERFACE®, EnDat2.1, 1Vpp without reference track
View
Connection
Signal name
Function
1
A+
max. 1.65 V
pp
track A analog positive
2
B+
max. 1.65 V
pp
track B analog positive
3
A-
max. 1.65 V
ss
track A analog negative
4
B-
max. 1.65 V
ss
track B analog negative
Tab. 6-43:
Pin assignment
Mechanical data
Spring terminal (connector)
Unit
min.
max.
Connection cable
Stranded wire
mm
2
0.2
1.5
AWG
24
16
Stripped length
mm
10
Tab. 6-44:
Mechanical data
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
176/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Connection points
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01