A
RBS0023 at X141
B
RKB0033 at X141
C
X141 not connected
D
E‑Stop wired at X37/X38 and configured in P-0-0300
E
E‑Stop not wired at X37/X38 and/or not configured in P-0-0300
1
Not an E‑Stop zone node, local E-Stop takes effect
2
E‑Stop zone beginner
3
E‑Stop zone node
Fig. 7-20:
Logic table of E‑Stop zone setup
See also Functional Description of firmware "E‑Stop function".
7.1.9
Motor fan for KSM02
Fans are not available for KSM02 motor-integrated servo drives.
7.1.10
Evaluation of motor encoders at KMS
KMS near motor servo drives evaluate sin-cos encoders 1 V
pp
.
HIPERFACE encoder: The maximum allowed nominal current consumption is
60 mA.
Encoders with reference track cannot be evaluated.
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
219/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Notes on project planning