Description
Symbol
Unit
Value
Derating vs. installation altitude:
At an installation altitude h > h
nenn
, the perform‐
ance data reduced by factor f are available.
At an installation altitude in the range
h
max_ohne
to h
max
, an isolating transformer has to
be installed at the drive system mains connec‐
tion.
Operation above h
max
is not allowed!
h
max_ohne
m
2000
h
max
m
4000
Simultaneous derating for ambient temperature
and installation altitude
Allowed;
reduce performance data with the product of factors f and F
Ta
(f × F
Ta
)
Relative humidity
%
5 … 95
Absolute humidity
g/m
3
1 … 29
Climatic category (IEC721)
3K4
Allowed pollution degree (IEC 60664‑1)
3 (only with connectors plugged in)
Maximum concentration of corrosive gases
According to degree of protection
Vibration sine: axial
Acceleration at 10 … 2000 Hz
1)
g
1
With
KMS: 3
Axial (A), radial (R)
Vibration sine: radial
Acceleration at 10 … 2000 Hz
1)
g
1
With
KMS: 3
Overvoltage category
III (according to IEC 60664-1)
1)
According to EN 60068-2-6
Tab. 4-8:
Ambient and operating conditions (KMS)
Ambient and operating conditions (KMV, KNK)
Description
Symbol
Unit
Value
Degree of protection (IEC 60529)
IP65
Use within scope of CSA / UL
For use in NFPA 79 applications only.
Temperature during storage
see
chapter 4.2.2 "Storing the components" on page
Temperature during transport
chapter 4.2.1 "Transporting the components" on
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
55/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
General data and specifications
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01