Description
Symbol
Unit
KMS03.1B-A036-P-D7-ET-
END-NN-NN-FW
KMS03.1B-B036-P-D7-ET-
END-NN-NN-FW
Rise of voltage at output with
U
LN_nenn
and 7.5 m motor cable
length phase-phase (10‑90%)
6)
dv/dt
kV/µs
5.00
Rise of voltage at output with
U
LN_nenn
and 7.5 m motor cable
length phase-ground (10‑90%)
7)
dv/dt
kV/µs
5.00
Output frequency range when
f
s
= 4 kHz
f
out_4k
Hz
0...400
Output frequency range when
f
s
= 8 kHz
f
out_8k
Hz
0...800
Output frequency threshold to de‐
tect motor standstill
8)
f
out_still
Hz
0...4
Maximum output current when
f
s
= 4 kHz
I
out_max4
A
36.0
Maximum output current when
f
s
= 8 kHz
I
out_max8
A
28.2
Continuous output current when
f
s
= 4 kHz
I
out_cont4
A
12.0
22.0
Continuous output current when
f
s
= 8 kHz
I
out_cont8
A
8.8
22.0
Continuous output current when
f
s
= 4 kHz; output frequency
f
out
< f
out_still
I
out_cont0Hz
_4
A
12.0
22.0
Continuous output current when
f
s
= 8 kHz; output frequency
f
out
< f
out_still
I
out_cont0Hz
_8
A
5.9
16.0
Last modification: 2016-03-08
1)
Observe supply voltage for motor holding brakes
2)
See information on "Rated power consumption control voltage
input at U
N3
"
3)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
4)
Also depending on firmware and control section; see parame‐
ter description "P‑0‑0001, Switching frequency of power output
stage"; see "P-0-4058, Amplifier type data"
5)
Plus dissipation of braking resistor and control section
6) 7)
Guide value, see following note
8)
See following note regarding output current reduction
Tab. 5-17:
KMS - Technical data
Rated power consumption control voltage input at U
N3
Plus motor holding brake, plus power consumption of externally
connected inputs/outputs, plus safety option
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
102/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Technical data of the components