10.15 RBS0023, connector for safety zone node
Tab. 10-16:
Connector RBS0023
RBS0023
Connector M12, 12‑pin, A‑coded;
mat. no.: R911335348
Connec‐
tion
Connected to
connection
Function
A: Coding
1
5
When a KSM/KMS with optional safety technology is to be
a safety zone node within a safety zone, the connection
point X141 must be equipped with the connector
RBS0023.
The connector RBS0023 jumpers the following connec‐
tions:
●
5 ↔ 1
●
7 ↔ 2
●
6 ↔ 10
●
11 ↔ 3
KSM/KMS without optional safety technology can be op‐
erated within a safety zone without the connector
RBS0023, because the signals are directly transmitted to
the next safety zone node via X103.1 and X103.2.
2
7
3
11
4
n. c.
5
1
6
10
7
2
8
n. c.
9
n. c.
10
6
11
3
12
n. c.
Tab. 10-17:
Function, pin assignment, properties
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
290/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Accessories