6
Connection points
6.1
System connection points
6.1.1
Connection point of equipment grounding conductor
Cabinet-bound drive systems
Dangerous contact voltage at device housing!
Lethal electric shock!
WARNING
The devices of the Rexroth IndraDrive Mi product range are devices with in‐
creased leakage current (greater than AC 3.5 mA or DC 10 mA).
Therefore, always install a stationary connection of the equipment grounding
conductor.
In a Rexroth IndraDrive Mi drive system, connect the equipment grounding
conductor connections of all devices and additional components to the equip‐
ment grounding system.
Risk of damage to the devices by spark dis‐
charge of static charges
NOTICE
In some applications (e.g., printing or packaging), high static charges can de‐
velop. Make sure that these charges can be directly discharged against
ground at their point of origin. Therefore, connect the
point of equipment grounding conductor
of the devices to the equipment
grounding system of the installation.