View
Con‐
nection
Signal name
Devices with
safety tech‐
nology
Signal name
Devices
without safe‐
ty technology
1)
Function
Female connector M12 (12‑pin,
D‑coded)
1
SI_Ch1
n. c.
Input for selection of channel 1 (connected to
X103.2.10)
2
SI_Ch2
n. c.
Input for selection of channel 2 (connected to
X103.2.8)
3
Zone_Br
Zone_Br
For the desired function, X141.3 has to be ac‐
cordingly controlled:
●
Safety zone beginner:
Input not connected
●
Safety zone node:
Short circuit to X141.11
(input voltage: 0 … 6 V)
●
"Release brake":
Short circuit to X141.9
(input voltage: 24 V ±20%)
4
24V
n. c.
Dynamization outputs power supply
5
SI_Ch1_In
n. c.
Input for selection of channel 1, preceding axis
(connected to X103.1.10)
6
0V_In
0V
2)
0V selection, preceding axis (connected to
X103.1.9)
7
SI_Ch2_In
n. c.
Input for selection of channel 2, preceding axis
(connected to X103.1.8)
8
Dyn_Ch1
n. c.
Channel 1 dynamization output
3)
9
24V_ZBr
24V_Br
Internal interface only;
24 V for "release brake" function
10
0V
0V
2)
Inputs and outputs power supply (connected to
X103.2.9)
11
GND_Zone
GND
For "safety zone node" function
12
Dyn_Ch2
n. c.
Channel 2 dynamization output
3)
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
156/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Connection points
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01