Clause / Requirement
Compliance
Signature
Automatic charging shall ensure that the
batteries are fully recharged to 80% of
their maximum rated capacity from the
fully discharged state in a period of not
more than 24 h.
Responsibility of the installer.
Adequate ventilation and protection
against corrosion and dangers resulting
from gases emitted by the batteries shall
be provided.
Responsibility of the installer.
5.7 Climate and environmental conditions
As all or part of the system may be
installed inside or outside buildings, under
various climatic and environmental
conditions, and exposed to possible
mechanical damage, full information on the
conditions under which the system is
required to operate shall be included in the
system specification. For tests, refer to
IEC60068-1 (environmental testing).
The Plena Voice Alarm System
specifications exceed the
environmental requirements
given by IEC60849.
When not otherwise specified, equipment
shall operate in accordance with the
system specification under the following
conditions:
a Control and amplification equipment
and associated battery power supplies:
–
Ambient temperature -5 °C to + 40
°C.
–
Relative humidity 25% to 90%.
–
Air pressure 86 kPa to 106 kPa.
b All other equipment:
–
Ambient temperature -20 °C to +55
°C.
–
Relative humidity 25% to 99%.
–
Air pressure 86 kPa to 106 kPa.
5.8 Marking and symbols for marking
Equipment shall be permanently marked
with information regarding its function.
Compliant.
Terminals and controls shall be
permanently marked with information
regarding their function, characteristics
and polarity.
Compliant.