Commands for Ducker
Read Write
Values
Description
/
PARA
M
/DSP
/
DUCKE
R_x
/ATTACK
/
VALU
E
R / W
5...1000 Attack time in ms
/BYPASS
/
VALU
E
R / W
0, 1
0 = Bypass not activated, 1 = Bypass
activated
/
DUCKINGLE
VEL
/
VALU
E
R / W
-100...-6 Ducking level in dB
/
GAINREDU
CTION
/
VALU
E
R
Gain reduction as full scale value (32
bit) Transform given value into dB by:
20 log (0x7FFFFF/ value)
/HOLD
/
VALU
E
R / W
10...200
0
Hold time in ms
/LINEMUTE /
VALU
E
R / W
0, 1
Mute of LINE input (0 = not muted, 1
= muted)
/MICMUTE
/
VALU
E
R / W
0, 1
Mute of MIC input (0 = not muted, 1 =
muted)
/MIXLINE
/
VALU
E
R / W
-30...0
Gain of LINE input
/MIXMIC
/
VALU
E
R / W
-30...0
Gain of MIC input
/RELEASE
/
VALU
E
R / W
5...1000 Release time in ms
/
THRESHOL
D
/
VALU
E
R / W
-15...21 Threshold in dB
IRIS-Net
DIGITAL MATRIX | en 469
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......