WATCHDOG
Watchdog error in DPA. This error type is logged according standards, press the CLEAR
button to reset the error.
FIRMWARE
The firmware version of the DPA is not compatible with the DPM firmware version. A
firmware update is recommended.
PROTECT
When the red PROTECT / REDUCTION indicator lights, one of the internal protections has
been activated.
COOLING
Temperature overload of the DPA.
POWER SUPPLY
MAINS
Power supply mains error.
POWER SUPPLY
BATTERY
Power supply battery error.
PROTECT
When the red PROTECT / REDUCTION indicator lights, one of the internal protections of the
output channel has been activated.
INPUT PILOT
DETECTION
This indicator lights when the pilot tone at the DIRECT input is missing.
OUTPUT PILOT
DETECTION
This indicator lights when the pilot tone at the amplifier output is missing.
The PILOT GEN button allows activating the pilot tone generator of the amplifier channels.
Default: Deactivated, 6 V, 19600 Hz
The property: PilotHighGain=1 allows to increase the pilot tone level to 12 V.
The property: PilotTone.Freq allows adjusting the frequency of the generated signal in the
range 15000 Hz to 25000 Hz.
GROUND FAULT
A ground fault error at the amplifier output occurred. Press the CLEAR button to reset the
error.
AEC INPUT PILOT
DETECTION
This indicator lights when the pilot tone at the AEC input is missing.
COLLECTED ERROR
STATE
The FAULT LED at the DPA front panel lights at the occurrence of this type of error.
Press this button to activate the COLLECTED ERROR STATE manually.
IRIS-Net
PROMATRIX 8000 | en 824
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......