Element
Description
Delay times can be entered directly in milliseconds
(ms) or samples. Alternatively, entering a distance in
inches (in) or meters (m) is possible as well. The
appropriate delay time is calculated, taking into
account the indicated Temperature.
Temperature allows setting the current ambient
temperature in degrees Celsius (° C) or degrees
Fahrenheit (° F). The two units are automatically
converted. The temperature parameter only takes
effect if a distance value has previously been entered.
In that case, the influence of the temperature is
automatically taken into consideration during delay
time calculation.
BYPASS either activates (button not engaged) or
deactivates (button engaged) the delay which allows
for a quick A / B comparison of the effect that set
parameters have on the sound characteristics.
DEFAULT resets the temperature to 20° C or 68° F
respectively.
IRIS-Net
DIGITAL MATRIX | en 390
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......