Graphic Display Indication
Element
Default
Range
Description
The switches "Show Load plot A" and "Show Load plot
B" turn the indication of the corresponding impedance
graphs ON or OFF.
The switches "Show Reference A" and "Show Reference
B" turn the indication of the corresponding reference
impedance graphs ON or OFF.
The switch V toggles the unit of the Y-axis between Ohm
and Volt.
1000 Ohm 50 Ohm...10
kOhm or 0.5 V...
100 V
DIAGRAM RANGE allows zooming in or out the diagram’s
impedance range (Y- axis).
Parameters and Indications for the Continuous Monitoring of the Load Connected
Element
Default
Range
Description
The load display indicates the quotient of measured voltage
and current (U/I).
This indication shows the actual measured load, the
progression, and the set value range. The orange needle
indicates the actual value. The bright green bar indicates
which loads have already been measured while being on-
line. A red indication signals that the value exceeded or fell
short of the set value range. The dark green area represents
the allowable value range for the load of the corresponding
power amp channel. The set HIGH THRESH respectively
LOW THRESH values define the limits for this value range.
Moving the cursor over the indication bar brings up a tool-
tip context menu showing the numerical value of the
lowest, the highest, and the actually measured load values.
Clicking with the right mouse button on the indication bar,
followed by a click on Reset, clears the previously
measured load values (bright green and red ranges
disappear).
The VOLTAGE display provides continuous indication of the
corresponding power amp channel’s output voltage.
The CURRENT display provides continuous indication of the
corresponding power amp channel’s output current.
IRIS-Net
REMOTE AMPLIFIER | en 214
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......