Element
Description
DEVICE NAME
Alphanumeric name of the P 64 within the Dante network (also
indicated in DANTE-Controller). Limitations: string must not start with
number, maximum of 32 characters.
OM-1 FIRMWARE Firmware version of the OM-1 module.
LATENCY
Latency setting for the OM-1 module. The settings 0.5 ms, 1.0 ms or
5.0 ms are available.
PRIMARY LINK
Indicates the Ethernet speed of the primary Ethernet interface.
SECONDARY
LINK
Indicates the Ethernet speed of the secondary Ethernet interface.
ONLINE STATUS
Green, if the connection to the OMNEO or Dante network is OK;
otherwise red.
CLOCK MASTER
Green, if the OM-1 is the clock master in the OMNEO or Dante
Network, grey, if another unit acts as clock master within the network.
Press the MASTER button if this OM-1 should be clock master in the
Dante network.
SYNC
Synchronizing the DSP system to an OMNEO or Dante network is not
possible.
WATCHDOG
The OM-1 is being reset because of a hardware or software failure.
INTERFACE
An error has been detected in the internal connection between P 64
and OM-1.
Network View DM-1 / OM-1
Click on Tools -> DanteConfiguration to open the Network View dialog. This dialog allows the configuration of
transmitters and receivers in a Dante network. Left clicking the node in the matrix where the transmitter channel’s
column and the receiver channel’s line meet with the mouse does connect an output to an input. Again clicking onto
the corresponding node disconnects inputs and outputs.
Dante networks are subject to a restriction. Only one transmitter channel can be connected to a receiver channel at a
time (mixing signals is not possible). However, connecting a transmitter channel to various receiver channels is
possible.
IRIS-Net
DIGITAL MATRIX | en 351
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......