Examples:
–
/POWER/SWITCH ON ; switches amp's power on
–
/TEMP/MODULE ? ; queries the remote control module temperature
–
/TEMP/MODULE 65 ; reply to query: 65 °C
–
/STFLAG/DEVICE/ACT ? ; queries operational state and error flags
–
/STFLAG/ACT POWER,GLOBAL ; reply to query: Power is On, Global Error detected (Collected Error in external
CAN-devices)
–
/STFLAG/GLOBAL ? ; queries for which external CAN-devices errors have been detected
–
/STFLAG/GLOBAL 3-4 ; reply to query: Collected Error Flags on amps 3 and 4 are set
DSP PARAMETER INDEX TABLE
Input channel A or B
Index
Parameter Description Value Range
Value Description
/IDX00
delay bypass
0 / 1
0 = ON, 1 = BYPASS
/IDX01
delay
1.68467...2000
ms
/IDX02
eq1 bypass
0 / 1
0 = ON, 1 = BYPASS
/IDX03
eq1 type
0...5
0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX04
eq1 slope
0...2
0 = 0dB bypass, 1 = 6dB, 2 = 12dB
/IDX05
eq1frequency
20...20000
Hz
/IDX06
eq1 gain
-18...12
dB
/IDX07
eq1 quality
0.4...40
/IDX08
eq2 bypass
0 / 1
0 = ON, 1 = BYPASS
/IDX09
eq2 type
0...5
0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX0A
eq2 slope
0...2
0=0dB bypass, 1=6dB, 2=12dB
/IDX0B
eq2frequency
20...20000
Hz
/IDX0C
eq2 gain
-18...12
dB
/IDX0D
eq2 quality
0.4...40
/IDX0E
eq3 bypass
0 / 1
0 = ON, 1 = BYPASS
/IDX0F
eq3 type
0...5
0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX10
eq3 slope
0...2
0=0dB bypass, 1=6dB, 2=12dB
/IDX11
eq3frequency
20...20000
Hz
/IDX12
eq3 gain
-18...12
dB
/IDX13
eq3 quality
0.4...40
/IDX14
eq4 bypass
0 / 1
0 = ON, 1 = BYPASS
IRIS-Net
REMOTE AMPLIFIER | en 227
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......