CONTROL INPUTS AND CONTROL OUTPUTS
Element
Description
This dialog indicates the actual states of the two freely programmable control inputs IN1 and IN2.
A green indicator signals "not active", i.e. the control input is open or "high". A red indicator signals
"active", in that case the control input is connected to the ground or "low".
This dialog is for manually controlling the two Open Collector control outputs OUT1 and OUT2.
Not engaged (blue) indicates that the control output is deactivated or highly resistive while engaged
(red) indicates that the control output is activated and connected to the ground (closed).
HINT: When a control output has already been programmed, the programmed function defines the
state of the control output and manual control is not possible.
For detailed explanation on how to program control inputs and outputs please refer to chapter Config & Info.
TEST GENERATOR PARAMETERS
The test generator allows outputting a selected test-tone at an adjustable level via the power amps channel A and/or
channel B which allows testing the cable run from the amplifier output to the connected loudspeaker systems as well
as testing the functionality of the loudspeaker components
Element
Default
Range
Description
Pink Noise Sine, White
Noise, Pink
Noise
Type selects the test tone's signal-type
440 Hz
20...20000 Hz
Freq defines the frequency of the sine signal. This parameter is not
available when White Noise or Pink Noise has been chosen as a test-tone
signal.
PRE/SOLO POST/MIX,
POST/SOLO,
PRE/MIX, PRE/
SOLO
MIX/SOLO determines whether the generated signal should be mixed
with an existing signal. PRE/POST determines if the signal should be
generated at the front (PRE) or the rear (POST) of the signal processing
chain.
0.775 V
0.001...2.451 V These controls are for setting output voltage [V] of the corresponding
amplifier outputs.
0 dBu
-60...+10 dBu
These controls are for setting output level [dBu] of the corresponding
amplifier outputs.
OFF
OFF, ON
These ON/OFF push-buttons activate or deactivate test-tone signal
output via corresponding amplifier channels.
CAUTION: Make sure to set a suitable output level, before activating
the generator. Extreme output levels can lead to permanent damage of
the connected loudspeaker systems!
Error Detection
Error detection lists the individual STATE of fault indications. Errors collected are amp failure, channel failure, cable
interruption, short-circuits, load deviation, ground fault, erroneous communication as well as fault messages of other
amps. A green STATE indicator signals normal operation. A red STATE indicator signals error detection.
IRIS-Net
REMOTE AMPLIFIER | en 284
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......