Element
Default
Range
Description
RAMP TIME
20 ms
1...20000 ms
Time constant of faders
RMS IN
10 ms
1...2000 ms
Time constant of RMS measurement of input signals.
RMS DUGAN
10 ms
1...2000 ms
Time constant of RMS measurement of dugan-gain weighted input
signals.
DIV DUGAN
10 ms
1...2000 ms
Time constant for weighting rate of input signal level, based on total
level.
DIV FINAL
10 ms
1...2000 ms
Time constant for rate of level change.
BAND-PASS FILTER
A band-pass filter is a device that passes frequencies within a certain range and rejects frequencies
outside that range. The frequency and quality of the filter is adjustable.
Element
Default
Range Description
Switches between frequency (magnitude) and phase
response (phase) indication.
Switch for selecting dB-axis scaling of 25 dB (± 12.5
dB) or 50 dB (± 25 dB).
1000Hz
20
Hz...20
kHz
FREQUENCY sets the center frequency of the band-
pass filter.
1
0.4...1
00
The Q-value sets the quality and thus the response of
the band-pass filter.
IRIS-Net
DIGITAL MATRIX | en 379
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......