OUTPUT PILOT
DETECTION
This indicator is for amplifier monitoring via external pilot-tone signal. In that case, internal
pilot-tone generation needs to be switched off to avoid interference between the two signals.
Detection and evaluation is performed at the amplifier output. The indicator lights green when
a 19 kHz pilot-tone signal with a level of at least -14 dBu / 150mV is detected. A missing pilot-
tone signal or a drop in its level below -14 dBu (threshold) results in error detection. The
indicator changes to red.
CAUTION: The externally fed pilot-tone signal passes through the entire signal path of the
remote amplifier, i.e. the signal is influenced by filtering and x-over settings. When setting
the external pilot-tone generator's level, make sure to mind possible amplification/
attenuation applied by internal filters.
COLLECTED ERROR
STATE
COLLECTED ERROR STATE is a collected fault message that combines all error types
detected for which the DETECT box had been mar- ked. The HOLD function allows keeping
the COLLECTED ERROR STATE for later evaluation while CLEAR clears the indication after
remedying the cause of the fault.
The COLLECTED ERROR STATE indication is identical to the indication in the Amplifier Status
column within the RCM-28 System Check Window.
OMNEO
The OMNEO Dialog integrates functions for configuring and monitoring the OMNEO network. A click on the OMNEO tab
selects the page while in the Setup & Control Window.
OMNEO ROUTING
Element
Description
DEVICE
Select the OMNEO device that is the signal source of the audio signal to be used in the RCM-28.
Different OMNEO devices can be selected for INPUT CHANNEL A or B.
CHANNEL
Select the OMNEO channel to be used in the INPUT CHANNEL A or B.
IRIS-Net
REMOTE AMPLIFIER | en 286
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956
Содержание IRIS-Net
Страница 1: ...IRIS Net en User Manual ...
Страница 2: ......
Страница 146: ...IRIS Net REMOTE AMPLIFIER en 146 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 148: ...IRIS Net REMOTE AMPLIFIER en 148 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 151: ...IRIS Net REMOTE AMPLIFIER en 151 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 153: ...Layer 5 Control Page IRIS Net REMOTE AMPLIFIER en 153 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 648: ...IRIS Net DIGITAL SOUND PROCESSOR en 648 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 693: ...IRIS Net DIGITAL SOUND PROCESSOR en 693 Bosch Security Systems B V User Manual 2017 05 3 20 F 01U 119 956 ...
Страница 992: ......
Страница 993: ......