Display Configuration | 11
Bosch Motorsport
DDU 10
99 / 188
11.7.4 Edit/Delete/Change priority of an Alarm
Perform the following steps:
1.
Click on the ‘Display’ tab and then on the ‘Alarm’ tab to go to the alarm configuration
window.
2.
Select the alarm area of the desired alarm.
The center of the alarm configuration window only shows the alarms of the selected
alarm area.
3.
Click on the alarm, which needs to be edited or deleted.
4.
To delete the alarm, click on the red cross.
5.
Change the properties of the alarm in the properties window on the right.
6.
To change the priority of the alarm, click the up/down arrow to rearrange the priority
list.
If the option “Show alarms” is ticked, the alarm with the highest priority will be visible
on the display page configurator. The visibility of the alarms will not be influenced by
the priority; the alarms will always rotate, if several conditions become true.
11.7.5 Resettable Alarm
An alarm can be configured as a resettable alarm. This means that the alarm can be linked
to a second conditional channel, which will hide the alarm, when the condition becomes
true.
To configure and use a resettable alarm, perform the following steps:
1.
Click on the ‘Display’ tab and then on the ‘Settings’ tab to go to the “DDU10 display
settings”
2.
Select your “Alarm reset channel”, which can be any boolean channel, like any other
conditional channel.
3.
Click on the ‘Alarms’ tab, to change to the alarm configuration window.
4.
Create an alarm or edit an existing alarm as described in the previous chapters, to ac-
cess the properties “Representation”.
5.
Change the “Reset mode” to resettable. The alarm will be displayed with a little cross
at the top right corner.
Important information on resettable channels:
– Only visible alarms can be reset. If several alarms are active, only the alarm which is
visible during the reset condition becoming true, will react to the reset.
– A reset alarm will not be shown again, if the alarm condition becomes true again, until
the next power cycle. Exceptions are, a change of the display page or if the retrigger
lock is enabled and the retrigger lock time is over.
11.8 User Interface Menu UIM
You can use the User Interface Menu (UIM) to conduct minor setting changes on the DDU,
like lap time or fuel reset.
How to configure the UIM
Perform the following steps, to set up an UIM on your device:
Содержание DDU 10
Страница 1: ...Display DDU 10 Manual Version 1 0 14 03 2019 ...
Страница 67: ...Mechanical Drawing 10 Bosch Motorsport DDU 10 67 188 10 Mechanical Drawing ...
Страница 187: ...Bosch Motorsport DDU 10 187 188 ...
Страница 188: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...