Math Channels and Conditional Functions | 12
Bosch Motorsport
DDU 10
105 / 188
– Although ‘p_br_front’ falls to 25, the value of ‘p_br_front_mx’ stays 30. This is caused
by the THEN-condition, because p_br_front_mx’ (30) is still bigger than
p_br_front’ (25).
– ‘p_br_front’ rises to 40. As ‘p_br_front’ (40) is bigger than ‘p_br_front_mx’ (30), the new
value for ‘p_br_front_mx’ is set to 40.
– As ‘p_br_front’ falls below 20, the IF-condition turns to FALSE. Now the OTHERWISE-
condition is triggered. Because the condition ‘p_br_front_mx’ sets the value of
‘p_br_front_mx’ and the value is already set to 40, nothing changes.
– When ‘p_br_front’ rises to 40, the IF-condition changes to TRUE again and triggers the
THEN-condition. Now the reset value (10) is used for ‘p_br_front_mx’ in the THEN-
condition.
– Because 40 is bigger than 10 the new value of ‘p_br_front_mx’ is 40.