Analog and Frequency Inputs | 6
Bosch Motorsport
DDU 10
41 / 188
Measurement label
Function
raw_
name
mV value of sensor
raw_
name
_fi
filtered mV value of sensor
name
physical value of sensor
name
_fi
filtered physical value
NOTICE
Measurement of ‘Revolution’ is similar.
6.3 Configuring computed sources
Computed sources receive data from a measurement channel rather than an input pin.
– Sensitivity/Offset calculation on input channel
– Characteristic curve calculation on input channel
– Computed vehicle speed
– Lap trigger (covered in a special separate section)
Example: Sensitivity/offset calculation on input channel
1.
Click ‘Measurement Sources’ in the Toolbox.
2.
Drag the ‘Sensitivity/Offset’ computed source from the Toolbox and drop it on ‘Com-
puted Channels’ in the DDU 10 Project Tree.
Drag + Drop
A ‘Computed Sensitivity/Offset Wizard’ opens.