Analog and Frequency Inputs | 6
Bosch Motorsport
DDU 10
29 / 188
6.2.2 Configuring a generic linear sensor
Example: Acceleration sensor 5 g
– From sensor data sheet - operating characteristics:
– Sensitivity 400 mV/g, Offset 2,500 mV
– The sensor has a linear output signal with sensitivity and offset
1.
Click on ‘Measurement Sources’ in the Toolbox.
2.
To expand the list of ‘I/O Channels’, click on ‘+’ in the DDU 10 Project Tree.
3.
Drag the “Sensitivity/Offset” analog signal source from the Toolbox and drop it on the
desired analog input channel in the DDU 10 Project Tree. A “Sensitivity/Offset Wizard”
opens.
4.
To activate the internal pullup-resistor, check the box. The internal pullup-resistor is
used to get a 5 V signal at the analog channel of the DDU 10. It allows you to use a
push-button. The fixed value of the internal pullup-resistor is 3,010 Ohm. If using an
additional external pullup-resistor, set up the overall resistance.
5.
Click ‘Next’ when done.
The second part of the “Sensitivity/Offset Wizard” opens.
Содержание DDU 10
Страница 1: ...Display DDU 10 Manual Version 1 0 14 03 2019 ...
Страница 67: ...Mechanical Drawing 10 Bosch Motorsport DDU 10 67 188 10 Mechanical Drawing ...
Страница 187: ...Bosch Motorsport DDU 10 187 188 ...
Страница 188: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...