Serial Trigger and Decode
88
10.2.2
SPI Trigger
This section provides a brief introduction for the operation of the SPI trigger.
1.
Press the
Setup
key to enter the
TRIGGER
function menu.
2.
Touch
Type
and select
Serial
.
3.
Touch
Protocol
and select
SPI
.
4.
Touch
Trigger Setting
softkey.
5.
Touch
Trigger Type
to select the trigger condition.
Function Menu
Settings
Explanation
Trigger Type
MISO
Master-In, Slave-Out
MOSI
Master-Out, Slave-In
Table 10.2
SPI Trigger Type
6.
Touch
Data Length
and turn the Universal Knob to set the length of a data. The range of data length is 4 to 96
bits.
7.
Set the value of the trigger data.
•
Set the value of a bit:
a.
Touch
Bit Roll
to select a bit in data.
b.
Touch
Bit Value
to set the value of the selected bit.
•
Set the value of all bits:
a. Touch
All Same
to set the value of all bits.
Function Menu
Settings
Explanation
Bit Value
0
High voltage level
1
Low voltage level
X
Don’t
care the voltage level
Table 10.3
SPI Bit Value
8.
Touch
Bit Order
to set the bit order (MSB or LSB).