Serial Trigger and Decode
126
Note:
Protocol Copy
The signal settings of decoding and triggering are independent. To synchronize
the settings between decode and trigger select
1.
The
DECODE COPY
menu will be displayed. (Figure
2.
Use the touchscreen to select
Copy To Trigger
or
Copy From Trigger
.
3.
Copy To Trigger
copies the decode settings to trigger.
4.
Copy From Trigger
copies the trigger settings to decode.
5.
Touch
option to return previous menu.
The synchronization is not automatic. If the settings at one
place change, a copy operation is necessary to re-synchronize.
Figure 10.62
Decode Copy
10.11.2
Manchester Serial Decode
Once the setup for the Manchester signal and trigger has been completed, the decoding operation must be setup.
1.
Touch Decode key to display the
Decode
menu.
2.
Use the touchscreen to enable the
Bus Operation
.
3.
Touch
Bus
to select either
Bus1
or
Bus2
.
4.
Touch
Display
to select the character encoding format of the decod
ing’s
result.
–
The
bus’s
vertical position can be adjusted using the
after selecting
Bus Position
.
–
Touch
Format
to set the format of the bus. (Default: Hexadecimal)
Interpreting the Manchester Decode
On the bus:
•
SYNC is displayed in pink
•
Header is displayed in green
•
DATA is displayed in white
•
Trailer is displayed in blue
In the list view:
•
Time
: The horizontal offset of the current data frame head relative to the trigger position.
•
Data
: Data words
•
Error
: Error type