Serial Trigger and Decode
107
3.
Touch
Bus
to select either
Bus1
or
Bus2
.
4.
Touch
Display
to select the character encoding format of the
decoding’s
result.
–
The
bus’s
vertical position can be adjusted using the
after selecting
Bus Position
.
5.
Touch
to return to the
Decode
menu.
6.
Touch
Display
option and choose the bus option selected in step 3.
7.
Touch
Lines
options and set the number of lines by
or the virtual keypad.
–
The range of the lines is 1 to 7.
8.
Touch
Scroll
option and turn the Universal Knob to navigate the available lines.
Interpreting the CAN FD Decode
On the bus
:
•
ID is displayed in green.
•
BRS (Bit Rate Switch) is displayed in light yellow.
•
ESI (Error State Indicator) is displayed in blue.
•
L (Data Length) is displayed in light yellow.
•
D (Data) is displayed in white.
•
CRC is displayed in blue.
•
Ack is displayed in pink.
•
The red point at the end of a segment indicates there is not enough space on the display to show the complete
content of a frame and some content is hidden.
In the list view
:
•
Time
: The horizontal offset of the current data frame head relative to the trigger position.
•
Type
: Type of the frame. Standard CAN frame is represented by "Std", CAN FD frame is represented by "FD", the
extended frame is represented by "Ext" and the remote frame is represented by "RTR".
•
ID
: Frame ID.
•
Length
: Data length.
•
Data
: Data bytes.
•
CRC
: Cycle redundancy check.
•
Ack
: Acknowledge bit.
Figure 10.39