Power Analysis
186
19.3
Inrush Current
A large current far greater than the stable current may flow through at the moment of switching on a power supply. The
large current is called inrush current. The current waveform when switching on is shown in figure
Figure 19.7
Inrush Current
19.3.1
Input Setup
1.
Touch
Input Setup
to display the signal menu shown in figure
2.
Touch
Input Voltage
to set the input voltage source.
3.
Touch
Input Current
to set the input current source.
4.
Touch
Expected I
to set the expected current value.
–
The range is 100 mA to 500 A.
–
The oscilloscope will set the trigger level to expected current/20 and the
vertical scale of the current channel to expected current/3.
5.
Touch
Max V in (RMS)
to set the maximum effective input voltage
(Vrms).
–
The range is 1 V to 1 kV.
–
The oscilloscope will set the vertical scale of the voltage
6.
Touch
Connection Guide Inrush
to display a diagram illustrating the
Figure 19.8
Input
Setup Menu
Содержание 2560B Series
Страница 1: ......
Страница 51: ...Digital Channels 51 Figure 8 9 Digital Bus...
Страница 127: ...Serial Trigger and Decode 127 Figure 10 63 Manchester Bus...
Страница 168: ...Reference Waveform 168 Figure 14 1 Recall REFB...