Power Analysis
185
√𝑋
2
+
𝑋
2
+
…
+
𝑋
2
= 100 %
∗
2
3
𝑋
1
𝑛
19.2.3
Parameter Description
For the first 40 harmonics, the following values are displayed:
•
Measured Value (RMS)
: The measured value displayed in the unit specified by the harmonic unit parameter
•
Limit Value (RMS)
: Limits specified by the selected standard
•
Margin (%)
: The margin specified by selected standard parameters. The margin value is (standard value - measured
value) / standard value * 100%
•
Pass/Fail State
: Determine whether the measured value is passed or failed according to the selected standard. The
rows in the table or the bars in the bar chart are rendered in different colors based on the pass / fail state. When the
value is greater than 85% of the limit but less than 100% of the limit, it is defined as a critical state.
•
Total Harmonic Distortion(THD)
:
where
𝑋
𝑛
is the nth harmonic, and
𝑋
1
is the basic component.
19.2.4
Input Setup
1.
Touch
Input Setup
to display the signal menu shown in figure
2.
Touch
Input Voltage
to set the input voltage source.
3.
Touch
Input Current
to set the input current source.
4.
Touch
Period
to set the periods displayed.
5.
Touch
Connection Guide
to display a diagram illustrating the procedure
setup. See figure
Figure 19.5
Connection Guide
Figure 19.6
Input
Setup Menu