conjunction with ambulatory ECG monitoring, is of particular use in the diagnosis of
disorders of the cardiac rhythm and the evaluation of syncope.
Contraindications
No absolute contraindications to performing an electrocardiogram, other than patient
refusal, exist. Some patients may have allergies, or more commonly, sensitivities to the
adhesive used to affix the leads; in these cases, hypoallergenic alternatives are available
from various manufacturers.
3) Recording ECGs during Defibrillation
This equipment is protected against the effects of cardiac defibrillator discharge to
ensure recovery, as required by test standards. The patient signal input of the acquisition
module is defibrillation-proof. Therefore, it is not necessary to remove the ECG electrodes
prior to defibrillation.
When using stainless steel or silver electrodes a defibrillator discharge current may cause
the electrodes to retain a residual charge causing a polarization or dc offset voltage. This
electrode polarization will block acquisition of the ECG signal. To avoid this condition, use
non-polarizing electrodes (which will not form a dc offset voltage when subjected to a dc
current) such as silver/silver-chloride types if there is a situation where there is a likelihood
that a defibrillation procedure will be necessary.
If polarizing electrodes are used, we recommend disconnecting the lead-wires from the
patient before delivering the shock.
Electrode defibrillation recovery is the ability of the electrode to allow the ECG trace to
return after defibrillation. We recommend using non-polarizing disposable electrodes with
defibrillation recovery ratings as specified in AAMI EC12 4.2.2.4. AAMI EC12 requires that the
polarization potential of an electrode pair does not exceed 100mV, 5 seconds after a
defibrillation discharge.
4) Product Features
- Print 12-channel (ch) cardiac signals with reports in: 3ch+1 rhythm, 3ch+3 rhythms,
6ch+1 rhythm, and 12ch rhythm patterns on A4 or Letter size printing paper.
- Record and print 12 channel rhythms continuously and simultaneously.
- Calculate heart rate, P-R-T axis and PR, QRS, QT and QTc widths from recorded signals
automatically and print them on a report for use in rhythm analysis.
- Get diagnostic reports using automatic detection functionality.
- Able to modify filter setting, signal sensitivity, printing speed, channel view settings and
rhythm settings, and print on previously recorded EKG signals to aid data analysis.
- Able to attach a battery so that the device can become portable.
- More than 200 patient‘s data can be saved and transferred to a PC through LAN as
well as through USB Memory.
- It offers various protocols to make it possible to link with hospitals‘ computing networks.
Also File Databases are strengthened.
Содержание CardioTouch3000
Страница 1: ...CardioTouch3000 Operation Manual Ver 7 00 2019 05 23 www ebionet com...
Страница 48: ...48 120 E3KOM 7 00 CardioTouch3000 Operation Manual Rhythm Report Form 3CH Rhythm Report Form 6CH...
Страница 49: ...49 120 E3KOM 7 00 CardioTouch3000 Operation Manual Rhythm Report Form 12CH Record Report Form 3CH 1 RHY...
Страница 50: ...50 120 E3KOM 7 00 CardioTouch3000 Operation Manual Record Report Form 3 CH 3 RHY Record Report Form 6 CH 1 RHY...
Страница 51: ...51 120 E3KOM 7 00 CardioTouch3000 Operation Manual Record Report Form 12 CH Record Report Form BEAT REPORT TEXT...