7.5 SPECIAL FUNCTIONS (menu S)
7.5.1 FUNCTION VENTILATION (menu S-1 to
S-3)
Definition: Additional–freely selectable–door position which
can be used either as a ventilation function for the garage or
as a partial opening position (for example for pedestrians on a
side sectional door).
Any desired door position can be selected for the ventilation
position between the end positions „Door Closed“ and „Door
Open“.
The function can only be employed when using a ra-
dio hand transmitter: a channel for the radio hand
transmitter(s) must be programmed for „Ventilation“
(see 6.1)! For the version of the device with a display the
function can alternatively be actuated over the display.
For activation of the ventilation function the door
should be initially moved with the drive into the desired
door position (no drive movement is possible in menu
S-1 bis S-3).
In operating mode „Automatic closing“ it is not possible
to programme the function (the door cannot be stopped
in the intermediate position): temporarily deactivate the
operating mode „Automatic closing“ for activation of
the ventilation function.
2.3.1 – 2.3.2 – 2.3.5 – 2.3.6 – 2.3.7
7.1 SETUP FORCE (menu F)
Setup of the force cut-off can be adapted in 9 stages to the gate
(see programming manual). The function automatic obstacle
detection / force cut-off must be checked after every manual
change to the force setup.
A manual change to the force setup may only be performed
with a measuring check according to EN 12445 by an expert in
the machine. Any change to the force setup must be documen-
ted in the inspection book.
Changing the closing force adjustment can lead to personal in-
jury.
Therefore, increasing the clamping force may only be perfor-
med by a competent person. After adjustment compliance with
the normative values with suitable measuring device must be
demonstrated and documented.
7.2 TIME TILL AUTOMATIC CLOSING (menu A)
Definition: The time period which expires between stop in the
end position „Door Up“ and the automatic closing of the door.
The hold open time can be set up in 5 stages from 10 sec. to
240 sec. .
The function is only available in the menu if the automatic clo-
sing is switched in menu b-3 = „active“.
7.3 WARNING TIME CAUTION LIGHT (menu U)
Definition: A delay which occurs between the start command
and the motor start in which certainly a connected caution light
(and/or the integral drive light) pre-flashes. The prewarning
time can be set up in various stages with separate times for
delay in the opening or closing direction.
The function is only available in the menu if the function of the
caution light is switched in menu b-6 = „active“; the function
can optionally be released through appropriate selection in
menu b-7 for the connection PK (external light) or the integral
drive light or both options (see 4.7.1).
7.4 LIGHT (menu L)
Definition: Regulates the afterglow time of the integral drive
light. The light can be set up in 7 stages from 0 sec. to 300 sec. .
This does not regulate the general function of the drive light
(on/off/flashing...).
Remote control of the integral drive light, see 7.5.3.
For use of the integral drive light with caution lights function
see 4.7.1.
7. PROGRAMME DRIVE FUNCTIONS
! PROFESSIONAL EXTENSIONS !
Содержание G 501
Страница 1: ...1 USER MANUAL WWW BERNAL DE BERNAL GERMANY 8 8 GB G 501...
Страница 2: ...2 GB Your comfort is our drive...
Страница 50: ...50 GB OVERVIEW OF THE STRUCTURE OF THE MAIN MENU LEVEL 1 04...
Страница 51: ...51 GB SETUP SETTING FORCE DISTANCE TRAVEL PATH AND FORCE CURVE MENU P SEE 5 1 ff 05...
Страница 52: ...52 GB SETUP TRANSMITTERS PROGRAMMING A HAND TRANSMITTER MENU C 1 SEE 6 1 06...
Страница 53: ...53 GB SETUP TRANSMITTERS DELETE A HAND TRANSMITTER MENU C 2 SEE 6 2 07...
Страница 54: ...54 GB SETUP TRANSMITTER DELETE ALL TRANSMITTERS MENU C 2 SEE 6 2 08...
Страница 57: ...57 GB SPECIAL FUNCTIONS FUNCTION VENTILATION MENU S 1 TO S 3 SEE 7 5 1 11...
Страница 59: ...59 GB 13 DRIVE PARAMETERS MENU b SEE 8 ff...
Страница 60: ...60 GB 16...